36
6 Set up with the display and adjustment module
FIBERTRAC 31 • Profibus PA
43833-EN-170126
by switching off the radiation. The switched-off radiation simulates a
100 % filling.
Because you have already set the background radiation to 0 in the
menu item: "
Setup/Background radiation
", the measured pulse rate
must be around 0 ct/s.
Show diagram
This menu item is only available if a linearization was already carried
out.
Show table
In this menu item you can show the individual value pairs of the
linearization.
Linearization - Delete
You can also delete individual linearization points.
Linearization - Modify
You can also modify individual linearization points.
Since the adjustment is very comprehensive, the menu points of
Function Blocks 1 (FB1) were put together in a submenu.
In menu item"
Channel
" you determine which measured value the
output refers to.
Setup - AI FB1
Setup - AI FB1 - Channel