Accessing Upstream and Downstream Settings
Depending on the Control Mode selected (e.g. Asymmetric mode), test settings for upstream and
downstream are also displayed
Burst (Back-to-Back) tab:
Max Rate:
The default value is 100%.
In the burst test, frames are always transmitted at the maximum rate for a given minimum and maximum burst duration.
Minimum Duration:
Selectable in the range 2 to 999 seconds. Default value is 2 seconds.
This is the duration of the first burst
Maximum Duration:
Selectable up to 999 seconds. The default value is 20 seconds.
This is the duration of the second burst, which must be greater than the minimum burst.
Repetitions:
Selectable in the range 1 to 100. The default value is 1.
This is the amount of times that the latency test will be repeated for each test frame size
RFC 2544 Setup - Burst Upstream
RFC 2544 Setup - Burst Downstream