Indicator Symbols
An M or S indicates that the test set is in Master or Slave Mode. A green SyncE icon indicates that the SyncE test is running and
a green 1588 icon indicates that the 1588 test is running. If the icon is flashing or solid red, there may be an issue with setup and
the test will not work.
12.2 Clock Measurement
The Clock measurement function is used for frequency comparison between the SyncE slave recovered clock to a reference
source. The results are measured in ppm (parts per million). This function can be used as a quick check prior to running a longer
duration wander measurement.
Clock Measurement Results
Note:
Clock and Wander measurements are only available in slave mode.
Src
- Select the source of the reference clock used for the clock measurement. Possible external clock sources can be: 2 MHz,
2 Mbps (E1 signal), 10MHz, 25MHz, 125MHz or GPS (1pps).