Throughput - Traffic Setup - Burst
Throughput - Traffic Setup - Single Burst
9.1.5 Error Injection Settings (Individual Streams)
Error injection can be performed during the test. The type of errors and error injection are configured in the Error Injection tab.
Once the test is running, error injection can be performed by pressing the Error Injection button on the right side of the screen.
Error type:
Select from Bit, CRC, IP Checksum (Layer 3, 4 only), Pause, TCP/UDP Checksum (Layer 4 only). With Pause
selected, the unit will transmit a pause frame when error injection icon is pressed. The Pause time duration is configurable
in units of 512 bit time. At Gigabit Ethernet speed, this is equivalent to 512 ns. For example, if pause time is set to 1000,
the pause duration will be set to 1000x512 ns.
Injection Flow:
The error injection flow determines how the selected errors will be injected. The user can select a single
error or a specific count.
Count:
The user will be able to configure the error count via numeric keypad.
Once the test is running, error injection is enabled by selecting the Error Injection icon from the action drop-down menu at the top
of the screen. Press the Error Injection button to inject errors at the predetermined settings.
/ e_Manual D07-00-050P RevD00
Page 60 of 115