Communication Setup - VaporTEK Interface
Setup with Laptop
39
12. Set Factory Defaults: Press ‘
3
’
This function sets all configuration parameter into default conditions.
•
M1 and M2 H/V-Inputs are set default 1000 RPM.
•
The Pulse Ratio is set to 136p/l.
•
The A/L - Ratio is set to 100%.
New Connection Hyperterminal
File Edit View Call Transfer Help
Print echo
Capture
NUM
CAPS
SCROLL
9600-8-N-1
Auto detect
Connected 0:02:44
2. Set Config
-------------
Pump Motor Type: VaporTEK
VTEK-RS422 Type: Slave Device
HV Nozzle Speed: M1 = 2500 rpm
HV Nozzle Speed: M2 = 2500 rpm
Set M1 - Input performance (0...250RPM x10):120
Set M2 - Input performance (0...250RPM x10):120
Do you want to save it?[Y/N]: y
Config has been stored successfully
Pump Motor Type: VaporTEK
VTEK-RS422 Type: Slave Device
HV Nozzle Speed: M1 = 1200 rpm
HV Nozzle Speed: M2 = 1200 rpm
New Connection Hyperterminal
File Edit View Call Transfer Help
Print echo
Capture
NUM
CAPS
SCROLL
9600-8-N-1
Auto detect
Connected 0:02:44
3. Set Factory defaults
-----------------------
Are you sure? [Y/N]
Factory defaults has been set