Description of Terminal Functions
Description of Terminal Functions
S Sens1
Motor S (MTR S) operator . Connects to the thin PURPLE wire of the Motor S operator.
S Sens2
Motor S (MTR S)operator. Connects to the thin BLUE or ORANGE wire of the Motor S
operator.
M Sens1
Motor M (MTR M)operator. Connects to the thin PURPLE wire of the Motor M operator.
M Sens2
Motor M (MTR M)operator. Connects to the thin BLUE or ORANGE wire of the Motor M
operator.
Sens +
Operator sensor power connection. A 5V output for connecting to the thin RED sensor
wireon both the MTR M and MTR S operators.
Sens -
Operator sensor power connection. A 0V output for connecting to the thin BLACK or GREY
sensor wire on both the MTR M and MTR S operators.
Safe CLS
CLOSING edge safety input. (A normally-closed potential-free input). For as long as a
connection between this input and COM is maintained the controller will behave normally.
When this connection is broken it will prevent the gate from closing if it is stationary, and will
stop and reverse the gate if it is closing. This input has no effect if the gate is opening.
(NOTE: If the Saf CLO function is not required a link must be fitted between Safe CLO
and COM for the controller to operate normally.*)
Safe OPN
OPENING edge safety input. (A normally-closed potential-free input). For as long as a
connection between this input and COM is maintained the controller will behave normally.
When this connection is broken it will prevent the gate from opening if it is stationary, and will
stop and reverse the gate if it is opening. This input has no effect if the gate is closing.
(NOTE: If the Safe OPE and reverse functions are not required a link must be fitted
between safe OPE and COM for the controller to operate normally.*)
* - When setting up the controller for the first time or after a full reset back to factory default
has been performed, the system will electronically override the Safety Inputs and allow the
system to function without the links. However if safeties are connected to either or both
inputs, thereafter there must be a normally closed circuit maintained for the system to
operate correctly. I.e. if beams are fitted and then removed, the circuit which is affected must
be replaced with a wire link to create the normally closed circuit.
LCK/STP
Holiday Lockout or gate STOP input. (A normally-closed potential-free input). For as long as
a connection between this input and COM is maintained the controller will behave normally.
But, when this connection to COM is broken all inputs are inhibited, and if the gate is moving
it will stop.
(NOTE: If the LCK function is not required a link must be fitted between LCK and COM.)
TRG
Trigger input. ( A normally-open potential-free input) Momentarily connecting this
input to COM will cause the gate to open or close depending on the
operating mode selected. For more information see the auto-close feature and modes of
operation.
PED
Pedestrian opening input. (A normally-open potential-free input). Momentarily connecting
this input to COM will cause one gate to open to the Pedestrian open position. For more
information refer to the Pedestrian feature.
FRX
Free exit input. (A normally-open potential-free input). Momentarily connecting this input to
COM will cause a gate which is closed, or closing, to open or re-open. If the gate is open, or
opening, the signal has no effect other than to reset the auto-close timer (if selected). Free
exit (FRX) never initiates a closing cycle. The only way to close a gate, if only the FRX input is
used, is to activate the auto-close feature on the controller.
LIT
LIT Activates the pillar light output. (A normally-open potential-free input). Momentarily
connecting this input to COM will cause the LIGHT relay to energize for a period of time as
set in the courtesy light timer menu. If the connection is made for a period exceeding 3
seconds the pillar light relay will latch and remain latched indefinitely until a new momentary
connection to COM is given.
PARAMETER DESCRIPTION
UNIT
MIN
DEFAULT
MAX
PED Open Distance
Gate Lock Enabled
PIRAC Enabled
IRB Ambush Alarm Enabled
IRBO Starts Wire-Less**
Courtesy Light Time
Diagnostic Screen Enabled
Remote Menu Locked
Gate Lock Type
SAF Common Enabled
IRB Ambush Alarm Hold-Off Time
IRBC Starts Wire-Less**
Courtesy Light Profile
Test Push-Button Enabled
Helix Mode Disabled**
Gate Lock Pre-Release Time
SAF Common Tests which Beams
IRB Break-In Alarm Enabled
LCK Starts Wire-Less**
Gate Lock Release Time
IRBO acts as IRBC
IRB Alarms Output
Gate Lock Location
Gate Lock Drive Type
PED Auto-Close Time
PED Pre-Open Delay Time
PED Pre-Close Delay Time
% (Full Open)
YES/NO
YES/NO
YES/NO
YES/NO
YES/NO
Minutes
YES/NO
YES/NO
B,C,P,S,L
h:mm:ss
YES/NO
YES/NO
M,S
Crt,A,B,C
YES/NO
YES/NO
s
s
C,O,C & O
C,O,C & O
YES/NO
YES/NO
AC,DC
NO
NO
NO
1
0:00:04*
NO
NO
24.0*
YES
YES
YES
255
YES
YES
9:59:59*
24.0*
NO
NO
YES
YES
0:02:00
NO
NO
Striker
NO
1
YES
Courtesy
YES
YES
0.0
IRBC Only
NO
YES
1.0
0.1*
0.1*
NO
BUZZER
Close Only
AC
30
100
240
240
240
10
0
0
0
0
2
5
s
s
s
* -Settings are fixed across standards
** -Settings are not configurable via the GUI
South African Standard Profile Continue
Table 1 Factory Defaults Schedule