Page 42
LED
External gate status indicator. (A low current output signal.) An output terminal which
provides a low current, drive (approx. 4,5V DC, 20mA) to a LED which can be used to
indicate the gate status remotely. If more than 3 LED's are required it is necessary to fit the
CP78 MULTI LED driver card. For more details on the feedback about the status of the gate
provided by the STATUS LED refer to pg 43.
Com
The COMMON termination point. All trigger signals etc. have their return path to one of the
COM terminals.
Aux 12V
Auxiliary power connection. Provides a +12V DC supply for auxiliary equipment such as a
radio receiver, photo cells etc, It is linked directly to the battery positive via a 3A resettable
fuse.
Safe Com
Used for switching the power supply to the safety beams. If automatic beam testing is
required, the negative power supply connection of the beam transmitters and receivers
must be wired to this point.
Sol
Solenoid strike or Magnetic lock. A solenoid strike lock or Magnetic lock can be connected
between 12V and SOL. Note that the maximum current draw allowed for the lock is 2A.
Should the solenoid lock or magnetic lock exceed this current rating it is necessary to use
an interposing relay.
(NB - Particularly with magnetic locks, ensure that the steady state current draw
calculated over a 24hour period and added to this, the quiescent current draw of the
controller, other peripherals and the usage of the motors, does not exceed the
current delivered by the charger. If necessary fit a separate supply to power the lock
using an interposing relay connected to the Sol input.)
Light
Pillar light connection. These two terminals provide a normally open potential free contact
which is generally used to switch on a pillar light (courtesy light). This contact is fuse
protected – refer to pg44 for fuse specifications.
Batt +
Positive battery connection. (Battery terminal normally indicated as + or RED)
Batt -
Negative battery connection. (Battery terminal normally indicated as - or BLACK)
MTR M+
Motor M operator power connection. (Thick BLUE wire).
MTR -
Motor M operator power connection. (Thick BLACK wire).
MTR S+
Motor S operator power connection. (Thick BLUE wire).
MTR S-
Motor S operator power connection. (Thick BLACK wire).
Page 43
LED Indicator Lights
LED Indicator Lights
The controller is fitted with diagnostic lights (LEDs) that assist with the set-up and maintenance of the gate.
Table 2 below provides a description and purpose of the indicator lights with figure 11 alongside, indicating the
location on the control
During Normal Operation
ON
OFF
SLOW REGULAR FLASH = Gate is opening
FAST REGULAR FLASH = Gate is closing
1 FLASH EVERY 2 SECONDS = Courtesy light latched on
2 FLASHES EVERY 2 SECONDS = Mains failure
3 FLASHES EVERY 2 SECONDS = Battery low
4 FLASHES EVERY 2 SECONDS = Collision shutdown
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
NAME
STATUS
S Sens2
M Sens1
M Sens2
Light
Light
Batt +
Batt -
Sens+
Sens-
Safe CLS
Safe OPN
Com
LCK/STP
TRG
PED
Com
FRX
LIT
LED
Com
Aux 12V
Safe Com
Sol
Table 2 Description of LED indicators
Figure 11 LED positions
= Gate open
= Gate closed
= Signal present
= No signal
= Opening Safeties clear
= Opening Safeties obstructed
= Closing Safeties clear
= Closing Safeties obstructed
= Signal present
= No signal
= Signal present
= No signal
= System ready to operate
= System locked
= Signal present
= No signal
STATUS
LED
TRG
Saf OPE
Saf CLO
FRX
PED
LCK/STP
LIT
Buzzer Feedback
The VECTOR 2 controller is equipped with an onboard buzzer which is used for various features and
functions on the controller. One of the functions it provides is audible diagnostic feedback as detailed
in the table below:
Multiple collision condition
Battery low condition
Holiday lock-out enabled
Buzzer emits a pulsed tone for a 5 second duration,
after the controller is activated in a battery low
condition.
Buzzer emits a continuous pulsed tone as soon as
a multiple collision shutdown is activated. The tone
will cease as soon as a valid trigger input is activated.
Buzzer emits a pulsed tone for a 5 second duration
when the controller is activated with this feature
enabled.
PARAMETER DESCRIPTION