Cabling Requirements
Cabling Requirements
Figure 6 Cabling Requirements
Figure 5 Minimum Installation Requirements
Page 17
1.
220V AC mains cable via mains isolator
Or
switch (3 core LNE 0,5mm²)*
2
Optional keypad ( 3 core 0,5mm multi-
Or
stranded).
Low voltage 16V AC battery charger
6.
Optional infrared beams or safety edge
2
supply (2 core 1,5mm²).
(3 core 0,5mm multi-stranded or 4
core 0.5mm² for CE compliance).
2.
Intercom cable (n1 + 6 core) to house.
7.
Optional intercom cable (n2+2 core
3.
MOTOR M (MTR M) or MOTOR S
0,5mm² multi-stranded) to gate station.
2
(MTR S) cable ( minimum, 2 core 2mm
+ 4 core 0,5mm² multi-stranded). See
8.
Optional electric lock. (2 core 0.5mm²)
note ¥
4.
Optional radio receiver cable (3 core
9.
Optional pillar light cable (3 core, size
2
0,5mm multi-stranded, optional). #
according to power reg).
5.
Optional pedestrian key-switch ( 2 core
2
0,5mm multi-stranded).
†
n1 = number of cores required by intercom.
n2 = number of cores required by intercom.
To dwelling
Mains
isolator
switch
Control
box
4
5
7
6
2
LEGEND
1
8
9
9
3
3
6
†
Mains isolator must be fitted less than 1m from controller
*
Increase cable thickness if pillar lights are to be installed.
Screened cable is always recommended to provide better protection against lightning -
earth one end of screening.
Domestic charger only.
# For optimum range an external receiver can be mounted on the wall.
¥ Centurion has available custom VECTOR cable order reference: CABLEVEC68
Install the gate operator only if:
1.
It will not pose a hazard to the public.
2.
There is sufficient clearance to a roadway and/or public thoroughfares.
3.
The installation will meet all municipal and/or local authority requirements once completed.
4.
The gate mass, length and application is within the operator specifications (see page 8).
5.
The wind loading specifications are not exceeded (see page 42).
6.
The gate is in good working order, vertically hung and swings freely.
7.
It can be installed to have sufficient clearance between moving parts when opening and closing to reduce the
risk of personal injury and entrapment.
8.
Pushbuttons or key switches, when required, must be positioned so that the gate is in line of sight of the
operator.
General considerations for the installation:
1.
Always recommend the fitment of additional safety equipment such as safety edges and safety beams, for
additional protection against entrapment or other mechanical risks.
2.
Check that no pipes or electrical cables are in the way of the intended installation.
3.
Check that enough space is available for the gate operator with the gate in the required open position.
(See diagram below).
4.
Check the strength of the mounting pillar and fit a wall adaptor kit where needed.
5.
If the swing gate leaf is longer than 2.5m , ensure that a lock can be fitted.
6.
Never fit the operator on the outside of the gate, where the public has access to it. (Follow the instructions for
an outward opening swing gate, if required.)
7.
For greater security consider fitting an optional high security kit.
8.
Consider where the gate bracket will be mounted. It might simplify the installation to fit the optional gate
adaptor kit.
Page 16
There must be 2 sets of beams. One across the driveway when the gate is closed and one when the gate is open.
Gate opening
90° or less
Pillar (Max.) *
Wall (Min.) #
Wall (Min.) *
Gate opening
110°
Gate opening 90° or less
Operator
V400
150mm
150mm
250mm
V500
335mm
Wall (Min.) # Pillar (Max.)*
Gate opening 110°
Operator
V400
150mm
150mm
145mm
V500
210mm
Wall (Min.) # Pillar (Max.)*
Minimum Installation Requirements
(Tables are based on gates shorter than 2.5m.
• For gates 2.5m to 3.0m long, reduce the maximum pillar thickness by 20mm.
• For gates 3.0m to 3.5m long, reduce the maximum pillar thickness by 40mm.
• For gates 3.5m to 4.0m long, reduce the maximum pillar thickness by 60mm.)
# - The typical minimum wall clearance required to fit the operator.
* - The maximum allowable pillar thickness on which to fit the operator.
Pillar (Max.) #