Power Configurations:
Extention/retraction
(no load):
Max. Output Force:
Max. Operations (day):
Standby Operations:
Standby period:
½ day
1 day
2 days
Typical Gate Opening/
Closing Time:
Operating Temp. Range:
Housing Protection:
Mass of Operator:
Operator Stroke:
DC Current Draw (Max):
Nominal Input Voltage:
12V DC
15A
27mm/sec
250kgf
V400: 5.5kg
V500: 5.9kg
V400: 400mm
V500: 500mm
V400: <14 Sec
V500: <17.5 Sec
-20°C to +60°C
IP55
Battery 40AH <200 cycles
Battery 40AH <200 cycles
Battery 7AH <115 cycles
Battery 7AH <85 cycles
Battery 7AH <7 cycles
NA
Battery 40AH <200 cycles
Battery 40AH <200 cycles
Battery 40AH <200 cycles
100*
12V DC
15A
27mm/sec
250kgf
200
V400: <14 Sec
V500: <17.5 Sec
V400: 5.5kg
V500: 5.9kg
V400: 400mm
V500: 500mm
-20°C to +60°C
IP55
7AH, 12V, CP84E
(Domestic)
7AH, 12V, CP84SM2A
(Light Industrial)
Standby period:
½ day
1 day
2 days
Double kit inc controller only
Battery 7AH <140 cycles
Battery 40AH <200 cycles
Battery 7AH <75 cycles
Double kit inc controller and 2 sets safety beams
Operator V400/V500
*
Limited by the charging rate
Higher capacity battery can also be used must be housed separately e.g. 40AH.
Page 6
Overall Dimensions
1400mm Extended
1400mm Extended
1000mm Retracted
1000mm Retracted
400mm Stroke
400mm Stroke
Model V400
100
95mm
All dimensions shown in millimetres
Model V500
1600mm Extended
1600mm Extended
1100mm Retracted
1100mm Retracted
100
95mm
All dimensions shown in millimetres
500mm Stroke
500mm Stroke
Figure 1 Overall Dimensions
Specifications
Specifications
Page 7
15A (fused)
18V DC
48mA
2A DC
3A (PTC)
Current Sense & Redundant Optical
Redundant Optical
-20°C to +60°C
Max. Motor Current Per Channel:
Max. Input Voltage:
Standby Current Draw:
Max. Solenoid Current Draw:
Max. Aux Output Current:
Collision Detection:
Position & Trajectory:
Temperature Range:
Control Card
Limited by maximum daily usage
Limited by maximum daily usage