INSTALLATION
Series 642
40/107
Edition 2017-11-24
813316EB
4. Data type of pressure and position values (optional)
The «data type of pressure and position» can be configured by ‘Control View’, ‘Control Performance
Analyzer’, or ‘Universal Hyper Terminal’.
The «set-command» is: «s:23xxy00000». The xxy value is the data type of a pressure and position
signal.
y: 0 = signed integer(32 bit), 1 = floating point (32 bit, IEEE-754 standard), default = 0
xx: signal number in the buffer
xx
Value
00
Pressure
01
Pressure sensor 1
02
Pressure sensor 2 (optional, only in case of 2 sensor version)
03
Position
04
Not used – reserved
05
Not used – reserved
06
Pressure setpoint
07
Position setpoint
08
Not used – reserved
09
Not used – reserved
10
Not used – reserved
11
Not used – reserved
The «get-command» is: «i:23xx». The answer returns the data type of a pressure and position signal
«i:23xxy00000». The y value is the current data type of buffer value xx.
Example «get-command» with Terminal: Get the data Type of Position setpoint:
If at start up the data type value in the memory is out of range the default value is
taken. In this case the data type is set to default value (0 = singed integer) and the get
command i:23 add a string “False”:
Содержание 642 Series
Страница 5: ...Series 642 813316EB Edition 2017 11 24 5 107...
Страница 103: ...Series 642 SPARE PARTS 813316EB Edition 2017 11 24 103 107 12 1 Drawing Sample picture All Item refer to chapter Drawing...
Страница 106: ...APPENDIX Series 642 106 107 Edition 2017 11 24 813316EB 13 Appendix No information entered on time...
Страница 107: ...Series 642 813316EB Edition 2017 11 24 107 107 This page left blank intentionally...