OPERATION
Series 642
72/107
Edition 2017-11-24
813316EB
5.1.1
Local operation
Local operation means that the valve is operated via the service port using a computer or the Service Box
2. When using a computer, a service cable and a software from VAT is required.
You can use our Software (freeware) 'Control Performance Analyzer' which can be downloaded from:
http://www.vatvalve.com/customer-service/informations-and-downloads/control-performance-analyzer.
These softwares are beneficial especially for setup, testing and maintenance.
How to start:
Connect service cable between PC and valve controller, start software and push button ‘LOCAL’ to
enable for operation. Then enter menu Sensor / Setup and do sensor configuration according to your
application to make sure that you get the correct pressure displayed.
‘
'Control Performance
Analyzer' supports:
-
Valve setup
-
Sensor setup
-
Pressure control
-
Interface setup
-
Manual control
-
Sequence ontrol
-
Numeric and
graphical
monitoring
-
Data recording
-
Data analysis
-
Advanced
diagnostic
When communication to service port is interrupted the valve will change to remote
operation. So when service cable will be disconnected or software will be shut down,
the valve returns automatically to remote operation. This may result in an immediate
movement of the valve depending on remote control.
Refer to «Accessories» for ordering numbers of service cable and Service Box 2.
Содержание 642 Series
Страница 5: ...Series 642 813316EB Edition 2017 11 24 5 107...
Страница 103: ...Series 642 SPARE PARTS 813316EB Edition 2017 11 24 103 107 12 1 Drawing Sample picture All Item refer to chapter Drawing...
Страница 106: ...APPENDIX Series 642 106 107 Edition 2017 11 24 813316EB 13 Appendix No information entered on time...
Страница 107: ...Series 642 813316EB Edition 2017 11 24 107 107 This page left blank intentionally...