MAINTENANCE
Series 642
92/107
Edition 2017-11-24
813316EB
7.2.2.1
Durability of power fail battery
The curves in the graph show the estimated life of Ultra Cap PFO in the worst condition (max. sensor
load = 1 A, valve heating temperature = 150 °C).
If the SPS is not fully loaded (< 1 A) or heating temperature of valve body is lower than 150 °C, the
corresponding life time curve will be somewhere in between the upper and the lower curve.
Therefore please determine the equivalent maintenance period for replacing the Ultra Cap battery
(Option board).
This graph shows estimated life of Ultra Cap PFO for reference and not as
guaranteed value.
0
20
40
60
80
100
120
20
25
30
35
40
45
50
Ambient temperature [°C]
D
u
ra
b
il
ity
[m
o
n
th
s
]
w/o SPS module,
valve unheated
with SPS module,
valve unheated
w/o SPS module,
valve heated
with SPS module,
valve heated
Содержание 642 Series
Страница 5: ...Series 642 813316EB Edition 2017 11 24 5 107...
Страница 103: ...Series 642 SPARE PARTS 813316EB Edition 2017 11 24 103 107 12 1 Drawing Sample picture All Item refer to chapter Drawing...
Страница 106: ...APPENDIX Series 642 106 107 Edition 2017 11 24 813316EB 13 Appendix No information entered on time...
Страница 107: ...Series 642 813316EB Edition 2017 11 24 107 107 This page left blank intentionally...