4.5.6.1
Digital input
Pin
Signal type
Description
3
Digital
input
This function will close the valve.
Valve will be in interlock mode as long as function is activated.
After deactivation of function it will remain effective until
- converse CC-Link control command have been received
The function is activated when optocoupler is ‘on’ in non inverted configuration.
The function is activated when optocoupler is ‘off’ in inverted configuration.
Configuration can be adjusted in local operation via service port with CV, CPA
or Hyper terminal. Refer to chapter: «LOGIC I/O configuration».
1
Digital ground
Ground for digital input. Connect switch to ground.
See also chapter: «LOGIC I/O».
The digital input is digitally filtered. Filter delay is 50ms. This means that digital signal
must be applied for at least
50ms to be effective. Refer to chapter:
«LOGIC I/O » for details about input circuit.
4.5.6.2
Digital output
Pin
Signal type
Description
2
Digital
output
This function will indicate that the valve is closed. If the function “ON” is
configured the output is continous on.
Configuration can be changed in local operation via service port with CV, CPA
or Hyper terminal. Refer to chapter: «LOGIC I/O configuration».
4
Digital common
Common for all digital output. C or – terminal of source with common.
See also chapter: «LOGIC I/O ».
4.5.7
Service port connection
The service port (connector: SERVICE) allows to connect the valve to a RS232 port of a computer.
This requires a service cable and software from VAT.
You can use our Software (freeware) 'Control Performance Analyzer' which can be downloaded from:
http://www.vatvalve.com/customer-service/informations-and-downloads/control-performance-analyzer.
Alternatively the VAT Service Box2 can be connected to the service port for setup and local operation.
The service port is not galvanic isolated. Therefore we recommend using this only for setup, testing and
maintenance and not for permanent control.
Refer also to chapter: «Local Operation» for details and to chapter «Spare parts / Accessories» for
ordering numbers of service cable, software and Service Box 2.
Use only screws with 4–40 UNC thread for fastening the service port connector.
Содержание 642 Series
Страница 5: ...Series 642 813316EB Edition 2017 11 24 5 107...
Страница 103: ...Series 642 SPARE PARTS 813316EB Edition 2017 11 24 103 107 12 1 Drawing Sample picture All Item refer to chapter Drawing...
Страница 106: ...APPENDIX Series 642 106 107 Edition 2017 11 24 813316EB 13 Appendix No information entered on time...
Страница 107: ...Series 642 813316EB Edition 2017 11 24 107 107 This page left blank intentionally...