General information
9
Värmebaronen Vedolux -350, -450 and -650
Technical data
Vedolux
350
450
650
Weight
empty
full of water
1053
1366
1 234
1 609
1609
2050
lb
lb
Water volume
37
44,9
52.8
gal
Fuel
length
moisture content
wood
19.7
16
±
8
in
%
Wood store
volume
depth
27.4
38.8
56.5
gal
in
21.7
Filling hatch
w x h 13.8 x 10.4 13.8 x 12,8 15.8 x 16.5 in
Burn time
with full wood store
3.4
3.8
3.6
h
Power
nominal
119.4
136,5
221.8
kBTU/h
Pressure
design
test
36.26
62.37
psi
psi
Temperature
max.
220
°F
Chimney requirements
height
draught during operation
diameter
≥
16.4
-15
ft
Pa
in
5.9
6
7.1
Flue gas temperature
nominal output
214
360
266
°F
Flue gas flow rate
1
0.99
1.3
oz/s
Operation, natural ventilation/fan
with flue gas fan
Condensing/non-condensing
non-condensing
Excess/negative pressure at flue gas outlet
negative pressure
Return temperature
min.
≥
122
°F
Temperature range
167 – 185
°F
Accumulator volume
min.
396
582
770
gal
Cooling coil,
incoming cold water
connection pressure
temperature
minimum cooling water volume
≥
29
< 60
≥
8.8
psi
°F
gal
Boiler class in accordance with EN 303-5
Class 5
Voltage
115 V~
±
10%, 60 Hz
Current consumption
max.
2
A
Power without any additional
appliances connected
operation, max.
standby
230
8
W
W
IP class
IPX1
Max. temperature thermal relay (STB)
breaking temperature
212 +0/-41
°F
Ambient temperature
during operation
0 – 86
°F
Noise level during operation
51
50
50
dB
Manufactured to
PED 97/23/EC article 3.3
Pressure drop, water side
Vedolux 350
q = 0.2 gal/s,
∆
t = 50°F: 0.17
q = 0.1 gal/s,
∆
t = 68°F: 0.03
psi
psi
Vedolux 450
q = 953.5 gal/h,
∆
t = 50°F: 0.15
q = 476.7 gal/h,
∆
t = 68°F: 0.04
psi
psi
Vedolux 650
q = 1320 gal/h,
∆
t = 50°F: 0.17
q = 660 gal/h,
∆
t = 68°F: 0.04
psi
psi
Certified by Guardien Fire Test Labs
UL 391, ETLM 78-1, ASTM E1509, CSA B-366.1,
Tested according to method 28 WHH PTS