This is how the control panel works:
All settings are set on the panel. It also displays
information on temperature and operation.
Get into the habit of always paying attention to what
the display shows in connection with all activities
relating to the boiler.
Press a key once to light up the display. Press twice to
use the key’s function.
Description
a. : Green indication, lights up when the boiler is
started with the
key.
Goes out when the boiler is switched off because
the wood has been burned up or with the
key.
b. : Yellow indication, lights up for a warning.
c. : Red indication, lights up for an alarm. No boiler
operation possible. Flashes when no correct
boiler operation is possible.
d. Display, shows operating data and settings.
When the boiler is switched off, the illumination
goes out after 15 minutes.
e.
: Used primarily to:
- start firing.
Used also for settings.
f.
: Used for emergency shutdown of the boiler,
for example when there is no water in the
heating system and if the O
2
probe or flue
gas temperature sensor is defective.
Used also for settings.
g.
: Used to access menus and confirm a
selection in a menu.
Control panel
g
f
d
e
c
a
b
+
−
Flue gas temperature
[°F] ###.#