Värmebaronen Vedolux -350, -450 and -650
Exit the menu with
. The display switches to
the operation display. This also happens if no key
is pressed for 30 min.
The menu is exited if a fault or over temperature occurs.
Information
Boiler set
[°F] ---.-
Setpoint for boiler temperature.
Aggregate test
Safety test
Settings
E N D
Boiler temp.
[°F] ---.-
Current boiler temperature.
Exhaust set
[°F] ---.-
Setpoint for flue gas temperature.
Exhaust temp.
[°F] ---.-
Current flue gas temperature.
O2 set
[%] --.-
Setpoint for oxygen content in flue gases.
O2
[%] --.-
Current oxygen content in flue gases.
CO2 set
[%] --.-
Setpoint for carbon dioxide content in flue gases.
(Calculated from O
2
setpoint)
CO2
[%] --.-
Current carbon dioxide content in flue gases.
Based on CO
2max
for wood being 20.3%.
Exhaust fan
ON/OFF
Operating status, flue gas fan.
Load pump
ON/OFF
Operating status, charging pump.
Primary motor
[%] --.-
Current opening position for primary air damper.
Second. motor
[%] --.-
Current opening position for secondary air damper.
Information - Current operating status