Installation
19
Värmebaronen Vedolux -350, -450 and -650
See ‘Menu system’ for procedure.
The test is available only when the boiler is not in
operation.
There must be no fire or embers in the
boiler when calibrating the O
2
probe.
Press
and
at the same time to end the test.
Calibration
[sek] ###
Aggregate test
Information
Aggregate test
O2 sensor +
Test end [+&-]
Calibrate, takes 10 minutes
→
No calibration,
on to next test step.
Safety test
Settings
E N D
Exhaust fan +-
Test end [+&-]
: fan started.
: fan stopped.
: next test step.
Load pump +-
Test end [+&-]
: charging pump started.
: charging pump stopped.
: next test step.
Primary motor +-
Test end [+&-]
: primary air damper opened
: primary air damper closed.
: next test step.
Second.motor +-
Test end [+&-]
: secondary air damper opened.
: secondary air damper closed.
: next test step.
C/O contact +-
Test end [+&-]
: relay contacts C - NO close (external heat source off).
: relay contacts C - NC close. (external heat source on).
: next test step.
Door opener -
Test end [+&-]
: open wood hatch’s lock.
: close wood hatch’s lock.
: next test step.
Lighting +-
Test end [+&-]
: display illumination on.
: display illumination off.
: next test step.
Display 1 +-
Test end [+&-]
: indication on.
: indication off.
: next test step.
Display 2 +-
Test end [+&-]
: indication on.
: indication off.
: next test step.
Display 3 +-
Test end [+&-]
: indication on.
: indication off.
: to ‘display when boiler is not in operation’.
Not used!
Not used!