TS
−
I Special servo drive for hybrid electro-hydraulic system of injection molding machine User Manual
40
Chapter 4 Parameters and debugging of servo drive
Function
code
number
Function code name
Factory
setting
Setting range
Unit
Prop
erty
Function code selection
User
setting
3: Issue via multi pump CAN;
4: Issue via RS485
5: Issue via CAN+485
P0.05 Digital speed preset speed
20 0
~
P0.13
rpm
×
P0.06 Method of enabling servo
0
0
~
1 /
○
0: Operation panel;
1: Terminal;
P0.07 Motor running direction command
0
0
~
1 /
×
0: Run forward; 1: Run reverse
P0.08 Flow rising time
0.10
0.01
~
15.00s
s
×
P0.09 Flow falling time
0.10
0.01
~
15.00s
s
×
P0.10 Pressure rising time
0.10
0.01
~
2.0 s
×
P0.11 Pressure falling time
0.10
0.01
~
2.0 s
×
P0.12 Trial running speed of M key
20
0-100
rpm
○
P0.13 System
Max
speed
2000 0
~
9999 rpm
×
Set according to the calculated flow
P1 group of machine configuration parameters
P1.00 Capacity of oil tank
40
0
~
350 cc/rev
×
P1.01 Output signal of pressure sensor
0
0
~
4 /
×
0
:
0
−
10V
;
1
:
1
−
10V
;
2
:
0
−
5V
;
3
:
1
−
5V
;
4
:
4
−
20mA
;
P1.02
Measure range of pressure
sensor
250
0.0
~
350.0 kgf/cm2
×
P1.03
Method of issuing pressure
command
1 0
~
5 /
×
0: Via digital panel (P0.05)
;
1: Via AI1 analog value
2: Via computer CAN
3: Via multi-pump CAN
4: Via RS485
5: Via multi mode CAN+485
P1.04 Pressure feedback instruction
1 0
~
5 /
×
0: Via digital panel (P0.05)
;
1: Via AI2 analog value
2: Via computer CAN
3: Via multi-pump CAN
4: Via RS485
5: Via multi mode CAN+485
P1.05 Pressure
setting
10.0
0.0
~
140.0 kgf/cm2
○
P1.06 Max pressure limit of machine
140.0
0
~
250.0 kgf/cm2
×
P1.07
Speed limit for pressure
discharging
50.0
0
~
500 rpm
○
P1.08 Low
pressure
5.0
0
~
10.0 kgf/cm2
○
P1.09 Speed for lower flow
0
0
~
50 rpm
○
P1.10
Pressure sensor error detection
time
1.5 0
~
5.0 s
○
Содержание TS-I Series
Страница 1: ...User Manual TS I series servo drive is introdution V T ...
Страница 2: ......