Chapter 3 Digital actuator button, display and motor learning
33
“Loc2”(P2.00=2) or “Loc3”(P2.00=3) is displayed.
2. Do not press any key for continuous 5 minutes.
3. Restart the drive
3.6 Lock/Unlock Keys
Lock
Keys
Set the function of locking keys
Select the P2.00 key locking functions:
0: Do not lock the keys on the operation panel and all the keys can be used;
1: Lock the keys on the operation panel and all the keys cannot be used;
2: Except multi-function key M, all the keys cannot be used;
3: Except RUN and STOP/RST keys, all the keys cannot be used.
Key Locking Function is Enabled
One of following three methods can be used to enable the key locking function:
1. Press ESC+PRG +
∧
at the same time (for shuttle type, turning clock wise is equivalent to
the
∧
key) to display “Loc1” (P2.00=1) or “Loc2”(P2.00=2) or “Loc3”(P2.00=3), the
operation panel is locked according to the setting method of P2.00. When P2.00=0, “Prot”
is displayed and the operation panel is not locked and only the password protection is
enabled.
2. Power on the drive again to lock the operation panel.
3. If no key is pressed within 5 minutes after setting the function code, the operation panel is
locked automatically.
Unlock
Keys:
Press ESC+>>+
∨
keys at the same time (for shuttle type, turning anti-clock wise is equivalent to
∨
key) to unlock.
3.7 Operation Panel Display and Key Operation
3.7.1 Classification of Display Status
There are 8 types of display status of operation panel:
SN
Status
Meaning
1
Display status of stopping parameters
Press >> key to switch the displayed parameters, P2.03 can be used to set
the displayed parameters.
2
Display status of running parameters
Press >> key to switch the displayed parameters, P2.02 can be used to set
the displayed parameters.
3
Display status of fault and alarm
In other 7 kinds of display status, if there is any fault happens, directly enter
this status.
4
Display status of first level menu
When the keys are not locked, in status of SN1, SN2, SN3 and SN7, press
PRG to enter.
5
Display status of second level menu
In the display status of first level menu, press PRG to enter.
6 Password
verification
status
If password protection is enabled, press PRG to enter in the display status of
first level menu.
Содержание TS-I Series