![V&T TS-I Series Скачать руководство пользователя страница 61](http://html1.mh-extra.com/html/vandt/ts-i-series/ts-i-series_user-manual_846023061.webp)
TS
−
I Special servo drive for hybrid electro-hydraulic system of injection molding machine User Manual
Chapter 4 Parameters and debugging of servo drive
49
Function
code
number
Function code name
Factory
setting
Setting range
Unit
Prop
erty
Function code selection
User
setting
Pd.09
Max current for weak magnetic
control
010
0.0
~
PA9.04*90%
A
×
Pd.10
Proportional coefficient for weak
magnetic adjustment
0.30
0.0001
~
30.000
/
×
Pd.11
Integration coefficient for weak
magnetic adjustment
0.500 0
~
10.000 /
×
Group d0 Fault Record Parameters
d0.00 Fault type record 2
0
0
~
62 /
*
d0.01 Fault type record 1
0
0
~
62 /
*
d0.02 Latest fault type record 0
0
0
~
62 /
*
Refer fault and alarm information list
d0.03 Bus voltage upon latest fault
0
0
~
999 V
*
d0.04 Actual current upon latest fault
0
0.0
~
9999 A *
d0.05
Running speed
upon the latest fault
0 0
~
30000 rpm
*
d0.06 Total power-up time on time
0
0
~
65535 kh
*
d0.07 Total operation time of the drive
0
0
~
65535 kh
*
d0.08
Record of maximum temperature
of heatsink
0 0.0
~
100.0
℃
*
d0.09
Record of maximum bus voltage
fluctuation
0 0
~
1000 V
*
d0.10 Reserved
0
30000
/
*
d0.11 Reserved
0
5
/
*
Group d1 Product Identity Parameters
d1.00 Serial
number
35355
8A1b
/
*
d1.01
Software version number of
control board
1000
0.00
~
99.99 / *
d1.02
Non-standard version number of
software of control board
2304
0
~
9999 /
*
d1.03
Software version number of
operation panel
2458
0
~
65535 /
*
d1.04
Software version number of
extension board
0 0
~
65535 /
*
d1.05 Manufacture’s bar code 1
0
0
~
9999 /
*
d1.06 Manufacture’s bar code 2
0
0
~
9999 /
*
d1.07 Manufacture’s bar code 3
0
0
~
9999 /
*
d1.08 Manufacture’s bar code 4
0
0
~
9999 /
*
d1.09
Operation panel copy
identification code
100
0
~
65535 /
*
d1.10
Control board software
identification code
0000
0
~
65535 /
*
d1.11 Reserved
0 0
~
65535 /
*
Group d2 Use of Display Parameters
d2.00 Temperature of heatsink 1
0
0.0
~
100.0
℃
*
d2.01 Terminal
count
value
0
0
~
65535 /
*
Содержание TS-I Series
Страница 1: ...User Manual TS I series servo drive is introdution V T ...
Страница 2: ......