TS
−
I Special servo drive for hybrid electro-hydraulic system of injection molding machine User Manual
10
Chapter 2 Installation and connection of servo driver
Figure 2
−
9, and then take out the cover in direction 2.
Mounting of cover
After connecting the cables of main circuit terminals and control circuit terminals, cramp the cover in
direction 1 as shown in Figure 2
−
10, press down the cover in direction 2 and then tighten the cover
screws.
Figure 2
−
9 Removal of cover Figure 2
−
10 Mounting of cover
Mounting of operation panel
Please refer to 2.3.1 Removal and mounting of operation panel.
"
Note:
Do not directly mount the cover with operation panel on the driver, otherwise, the operation panel will
have poor contact.
2.3.4 Open and Close of Doors of TS
−
I
−
4T176A and Above Power Class Driver with
Sheet-metal Enclosure
Opening of the door
Press the latch following direction 1 in Figure 2
−
11 and open the door following direction 2.
Removal of operation panel
The operation panel is connected to the control board through the standard network cable and will not
interfere with the open/close of the door. To remove the operation panel, refer to section 2.3.1 Removal
and Mounting of Operation Panel
Mounting of cover
After connecting the cables of main circuit terminals and control circuit terminals, close the door following
direction 1 in Figure 2
−
12, and then press down the latch following direction 2 to lock the door.
Figure 2
−
11 opening the door
Figure 2
−
12 closing the door