![background image](http://html1.mh-extra.com/html/vamp/265/265_operation-and-configuration-instructions_3326045215.webp)
Technical description
12 Order information
VM265.EN011
VAMP 24h support phone +358 (0)20 753 3264
215
12.
Order information
When ordering, please, state the ordering code:
VAMP 265 ORDERING CODE
VAMP 265
-
VAMP 265
Nominal current, HV & LV side [A]
1
=
1A & 1A
3
=
1A & 5A
4
=
5A & 1A
5
=
5A & 5A
Nominal earth-fault currents Io & I'o [A]
A
=
5A & 5A
B
=
5A & 1A
C
=
1A & 5A
D
=
1A & 1A
Frequency [Hz]
7
=
Standard relay
Supply voltage [V]
A
=
40.. 265Vac/dc
B
=
18.. 36Vdc
C
=
40.. 265Vac/dc + ARC Protection
D
=
18.. 36Vdc + ARC Protection
E
=
40.. 265Vac/dc + DI19, DI20 + arc channel, Optional
F
=
18.. 36Vdc + DI19, DI20 + arc channel, Optional
Optional hardware
A
=
None
B
=
Plastic/Plastic serial fibre interface
C
=
Profibus interface
D
=
RS 485 interface (4-wire)
E
=
Glass/Glass serial fibre interface
F
=
Rx Plastic/Tx Glass serial fibre interface
G
=
Rx Glass/Tx Plastic serial fibre interface
H
=
RJ-45 10Mbps ethernet interface
M
=
RJ-45 10Mbps ethernet inc. IEC 61850
O
=
LC 100 Mbps ethernet fibre interface inc. IEC 61850
P
=
RJ-45 100Mbps ethernet interface inc. IEC 61850
R
=
2 x LC 100 Mbps ethernet fibre interface inc. IEC 61850
S
=
2 x RJ-45 100 Mbps ethernet interface inc. IEC 61850
Optional software
A
=
Version 2 firmware (#
C
=
Version 6 firmware (*
E
=
Standard firmware
M
=
Standard firmware, Motor functions
Note:
(* Optional hardw are, A-H available
(# Optional hardw are, A-G available
Accessories :
Order Code
Explanation
Note
VEA3CGi
External ethernet interface module
VPA3CG
Profibus interface module
VSE001
Fiber optic Interface Module
VSE002
RS485 Interface Module
VSE003
RS485 Interface Module, Ext I/O interface
VSE009
External DeviceNet interface module
VIO 12 AB
RTD Module, 12pcs RTD inputs, RS 485 Communication (24-230 Vac/dc)
VIO 12 AC
RTD/mA Module, 12pcs RTD inputs, PTC, mA inputs/outputs,
RS232, RS485 and Optical Tx/Rx Communication (24 Vdc)
VIO 12 AD
RTD/mA Module, 12pcs RTD inputs, PTC, mA inputs/outputs,
RS232, RS485 and Optical Tx/Rx Communication (48-230 Vac/dc)
VX003-3
RS232 programming cable (Vampset, VEA 3CGi)
Cable length 3m
VX004-M3
TTL/RS232 converter cable (PLC, VEA 3CGi)
Cable length 3m
VX007-F3
TTL/RS232 converter cable (VPA 3CG)
Cable length 3m
VA 1 DA-6
Arc Sensor
Cable length 6m
VAM 16D
External LED module
Disables rear local communication
VYX076
Raising Frame for 200-serie
Height 40mm
VYX077
Raising Frame for 200-serie
Height 60mm
VYX233
Raising Frame for 200-serie
Height 100mm
V200WAF
V200 w all aseembly frame
(For OLD porjects)
(See Firmware revision history)
Содержание 265
Страница 2: ...VM265 EN011...
Страница 214: ...11 Construction Technical description 214 VAMP 24h support phone 358 0 20 753 3264 VM265 EN011 11 Construction...