74
TECHNIC
AL SPECIFIC
ATIONS
FAN INPUT POWER
Product titles
Vallox 101 MV R
Vallox 101 MV L
Product numbers
4102189
4102197
HVAC code
7912119
7912120
Additional heating
radiator
–
Air volumes
Supply air
Extract air
90 l/s, 324 m3/h, 100 Pa
98 l/s, 353 m3/h, 100 Pa
Fans
Supply air
Extract air
0.115kW, 0.9A EC
0.115kW, 0.9A EC
Electrical connection
230V, 50Hz 8,3 A
(power plug)
Operating efficiencies
Annual efficiency
Supply air efficiency
Specific Fan Power (SFP)
70 %
82 %
1,0 (38 dm3/s)
Enclosure protection
class
IP34
Filters
Supply air
Extract air
G4 and F7
G4
Post-heating radiator
Power, 1500 W
Heat recovery bypass
Automatic
Preheating radiator
–
Weight
50 kg
Dimensions (width x
height x depth)
598x447x596mm
Sound power level in the supply air duct
by octave band L
w
, dB
Sound power level in the extract air duct
by octave band L
w
, dB
Adjustment position
4 %
14 %
22 %
33 %
41 %
50 %
55 %
66 %
75 % 100 %
4 %
14 %
22 %
33 %
41 %
50 %
55 %
66 %
75 % 100 %
Air flow dm
3
/s (l/s)
8,6
15
16,9
37,7
45,1
53,5
57,3
67,4
73,3
82,3
11,3
24,4
34,3
45,6
55,6
65,9
72,6
83
91,5
99,2
Air flow m
3
/h
30,96
54
60,84 135,72 162,36 192,6 206,28 242,64 263,88 296,28 40,68 87,84 123,48 164,16 200,16 237,24 261,36 298,8 329,4 357,12
Medium
frequency
of the
octave
band Hz
63
56
58
63
67
70
72
75
77
79
80
62
53
56
58
61
64
67
68
70
71
125
52
62
63
65
67
69
71
74
76
78
52
58
58
61
64
67
69
70
73
74
250
44
52
57
64
70
66
70
71
72
74
35
45
50
57
60
60
62
62
62
63
500
40
49
53
58
61
64
65
69
71
74
27
34
40
44
48
51
53
55
57
62
1000
32
41
46
51
55
58
60
63
67
68
16
23
28
33
36
39
42
44
46
48
2000
24
34
40
47
51
55
57
61
63
65
14
17
23
29
32
36
38
41
43
44
4000
23
25
31
38
43
48
50
55
57
60
16
16
17
21
24
28
31
34
36
39
8000
21
21
23
30
35
41
44
51
53
56
20
20
20
20
20
21
22
24
26
29
L
W
, dB
L
WA
, dB(A)
58
64
67
71
74
75
78
80
82
84
62
59
61
64
67
69
72
73
75
77
41
50
54
60
64
65
67
70
73
75
39
43
45
50
54
55
57
58
59
62
Sound pressure level, in decibels (A) coming through the envelope from the room in which the unit is installed (10m
2
sound absorption)
ADJUSTMENT POSITION / AIR FLOWS (supply/extract)
Adjustment position
4 %
14 %
22 %
33 %
36 %
50 %
55 %
66 %
75 %
100 %
Air flow dm
3
/s (l/s)
13/15
21/24
29/32
39/41
43/46
55/58
60/62
69/72
76/78
84/85
Air flow m
3
/h
46,8/54
75,6/86,4
104,4/115,2
140,4/147,6
154,8/165,6
198/208,8
216/223,2
248,4/259,2
273,6/280,8
302,4/306
L
pA
, dB (A)
21
26
30
36
38
42
43
46
48
50
Input power (total) (W)
Air flow (max) (dm3/s)
SFP =
SFP rate (Specific Fan Power)
recommended value <2.0 (kW m
3
/s)
41%
33%
50%
55%
66%
75%
100%
14%
4%
22%
50
100
150
200
250
300
350
0
10
20
30
40
60
70
80
90
100
SFP: 1,0
50
36
72
108
0
144
180
216
252
288
324
360
(l/s)
SFP: 1,5
SFP: 2,0
B
A
SFP: 1,8
50
100
150
200
250
36
72
108
0
144
180
216
252 288 324 360
B
A
4%
14%
22%
33%
41%
50%
55%
66%
75%
100%
Volume flow rate
Power (W)
SUPPLY/EXTRACT AIR VOLUMES
SOUND VALUES
TECHNICAL SPECIFICATIONS
Volume flow rate
(dm
3
/s)
Pressure loss in ducts. Total pressure (Pa)
extract air
supply air
Содержание Vallox TSK Multi 80 MV
Страница 102: ...CONFORMITY CERTIFICATES...
Страница 103: ......
Страница 104: ......
Страница 105: ...105 Vallox Oy All rights reserved...
Страница 106: ...106...
Страница 107: ...107 Vallox Oy All rights reserved...