MOUNTING ON THE WALL
NOTE
• Avoid mounting the unit on a hollow, echoing partition wall or
on a bedroom wall, or prevent the conduction of sound.
• The minimum distance between the top of the unit and the
finished ceiling surface is 30 mm. Note that during mounting
the unit rises 10 mm higher than the final height.
Mount the ventilation unit on the wall with a mounting plate, as
shown in the adjacent figure. Make sure that the unit is horizontally
level after mounting.
INSTALLING THE COOKER HOOD
The cooker hood is installed on the bottom of the ventilation unit
with finger nuts (A), which are included in the accessory bag.
1. Open the bottom plate of the cooker hood, on which the
grease filter is mounted.
2. Lift the cooker hood against the bottom of the ventilation
unit. Feed the connection cord (B) at the same time inside the
cooker hood.
3. Fasten the cooker hood in place with finger nuts.
4. Pull the connection cord in place. Use line protection (C) where
required.
Observe in the figure:
1. Condensing water outlet
2. Exit hole for the condensing water outlet
3. Damper
MEASURING TUBES
The accessories delivered with the unit include four airflow
measuring tubes. These can be inserted in the ducts to allow for
easier ventilation adjustment.
WATER SEAL
NOTE
The Vallox Silent Klick water seal package is delivered with the
unit. Installation instructions for the water seal are enclosed
with the packaging, and can also be found online at www.vallox.
com. When the alternative water seal installation method is used,
the ring seal and the locking part must be moved to the pipe
connection part that is mounted on the wall.