User's Guide ______________________________________________________________________
62 __________________________________________________________________ M210482EN-B
D:
b23
(0080 0000)
Window contaminated (W)
b22
(0040 0000)
Battery low (W)
b21
(0020 0000)
Transmitter expire warning (W)
b20
(0010 0000)
Heater or humidity sensor failure (W)
C:
b19
(0008 0000)
High radiance warning together with b02 (W)
b18
(0004 0000)
Engine, receiver, or laser monitor failure warning
(W)
b17
(0002 0000)
Relative Humidity is high > 85 % (option) (W)
b16
(0001 0000)
Light path obstruction or receiver saturation (also
receiver failure active, b29) (A)
B:
b15
(0000 8000)
Blower failure (W)
b14
(0000 4000)
(spare) (W)
b13
(0000 2000)
(spare) (W)
b12
(0000 1000)
(spare) (W)
A:
b11
(0000 0800)
Blower is ON
b10
(0000 0400)
Blower heater is ON
b09
(0000 0200)
Internal heater is ON
b08
(0000 0100)
Units are METERS if ON, else FEET
9:
b07
(0000 0080)
Polling mode is ON
b06
(0000 0040)
Working from battery
b05
(0000 0020)
Always 0 (Single sequence mode is. N/A)
b04
(0000 0010)
Always 0 (Manual settings are effective. N/A)
8:
b03
(0000 0008)
Tilt angle is > 45 degrees (W)
b02
(0000 0004)
High radiance warning together with b19. (W)
b01
(0000 0002)
Manual blower control
b00
(0000 0001)
(spare)
3RD LINE
↵
= End-of-Text and Carriage Line Feed
CT25K Data Message No. 6
Message number 6 is similar to message number 1 but extended with a
sky condition line (see section Sky Condition Algorithm). For an
interpretation, see section CT25K Data Message No. 1 on page 60.
The following is an example of message number 6 format:
CTA2060
☺
↵
1st line
11 char.
30 01230 12340 23450 FEDCBA98
↵
2nd line
31 char.
3 055 5 170 0 /// 0 ///
↵
3rd line
30 char.
↵
4th line
3 char.
-------------------
total 75 characters