Set-up 4
0020181589_04 auroCOMPACT Installation and maintenance instructions
9
4.3
Unit dimensions
599
G¾”
G¾”
G¾”
G¾”
G¾”
388
698
126
A
35
B
C
D
E
140
140
40
85
70 70
80
65
10-20
595
Unit dimensions
150L
190L
Dimension
(A)
1,640 mm
1,880 mm
Dimension
(B)
941 mm
1,182 mm
Dimension
(C)
770 mm
1,010 mm
Dimension
(D)
1,577 mm
1,816 mm
Dimension
(E)
1,627 mm
1,866 mm
4.4
Minimum clearances
C
D
C
A
B
D
E
F
G
A
160 mm
B
425 mm
C
20 mm; (
≥
300 mm)
D
600 mm
E
165 mm (air/flue pipe,
60/100 mm diameter)
275 mm (air/flue pipe,
80/125 mm diameter)
F
40 mm
G
70 mm
4.5
Clearance from combustible components
It is not necessary to maintain a clearance between the
product and components made of combustible materials that
goes beyond the minimum clearances (
→
Page 9).
4.6
Unit dimensions for transport
A
Unit dimensions for transport
150L
190L
1,760 mm
1,985 mm
4.7
Transporting the unit
Danger!
Risk of injury due to carrying heavy loads.
Carrying heavy loads can cause injuries.
▶
When transporting heavy units, observe
all valid laws and other regulations.