31
Installation and maintenance instructions auroSTEP plus 0020077748_FT1
12.2 Sensor
characteristics
Cylinder sensors Sp1 and Sp2, Type NTC 2.7 K
Sensor characteristic
Resistance value
0°C
9191 ohm
5 °C
7064 ohm
10 °C
5214 ohm
20 °C
3384 ohm
25°C
2692 ohm
30°C
2158 ohm
40°C
1416 ohm
50 °C
954 ohm
60°C
658 ohm
70 °C
463 ohm
80 °C
333 ohm
120 °C
105 ohm
Table 12.2 Characteristics of cylinder sensors Sp1 and Sp2
Collector sensor VR 11, Type NTC 10 K
Sensor characteristic
Resistance value
-20 °C
97070 ohm
-10 °C
55330 ohm
-5 °C
42320 ohm
0°C
32650 ohm
5 °C
25390 ohm
10 °C
19900 ohm
15 °C
15710 ohm
20 °C
12490 ohm
25°C
10000 ohm
30°C
8057 ohm
35 °C
6532 ohm
40°C
5327 ohm
50 °C
3603 ohm
60°C
2488 ohm
70 °C
1752 ohm
80 °C
1258 ohm
90 °C
918 ohm
100 °C
680 ohm
110°C
511 ohm
120 °C
389 ohm
130 °C
301 ohm
Table 12.3 VR 11 collector sensor characteristics
12.3
Flat collector VFK 135 D
Units
VFK 135 D
Absorber type
Serpentine horizontal
Dimensions (L x W x H)
mm
1233 x 2033 x 80
Weight
kg
37
Volume
l
1.34
Max. pressure
bar
10
Stagnation temperature
°C
200
Gross area
m
2
2.51
Aperture surface area
m
2
2.35
Absorber surface area
m
2
2.33
Absorber
mm
Aluminium (vacuum
coated) 0.5 x 1178 x
1978
Coating
High selective (blue)
α
= 95 %
ε
= 5 %
Glass covering
mm
3.2 (thickness) x 1233 x
2033
Glass type
Solar safety glass (pris-
matic structure)
Transmission
%
τ
= 91
Back wall insulation
mm
W/m
2
K
kg/m
3
Mineral wool
(coated black)
40
λ
= 0.035
ρ
= 55
Edge insulation
none
Efficiency
η
o
%
80
Heat capacity
Ws/m
2
K
4152
Heat loss factor (k
1
)
W/m
2
K
3,7
Heat loss factor (k
2
)
W/m
2
K
2
0,012
Table 12.4 Technical data for VFK 135 D flat collector
1
0,8
η
0,6
0,4
0,2
0
0
0,02
0,04
0,06
T
m
* [m
2
K/W]
0,08
0,1
Fig. 12.1 Solar collector test in accordance with
DIN EN 12975-2:
Efficiency characteristic at an irradiation intensity of
800 W/m
2
, based on an aperture area of 2.35 m
2