19
Installation and maintenance instructions auroSTEP plus 0020077748_FT1
Display
Setting by turning the knob
Setting range
Default setting
Activation of anti-Legionella programme.
0 [Off], 1 [Day] (not relevant for
the PROMOTELEC version), 2
[Night]
0 [Off]
Setting of filling mode duration
3 - 9 min
9 min
Determines whether booster pump is con-
nected
0 [not connected], 1 [connect-
ed]
1
Select number of collectors
1 to 3
3
Setting of collector pump blocking time
1 - 60 min
10 min
Activation of the reheating delay
0=deactivated; 1=activated
0
Setting the current day
1-31
1
Setting the current month
1-12
1
Setting the current year
2000-2215
2000
Table 6.1 System parameters (continued)