11
Virtual Terminal (ISOBUS)
11.1
The home screen
Figure 11.1 VT home screen
The screen shows a fully equipped machine.
The home screen
The home screen is the view shown whilst operating All
the information that it is important to monitor is shown
here, and all necessary settings can be made here too.
A. Display for control and monitoring.
B. Function buttons for settings when drilling.
C. Navigation buttons that open submenus for basic
settings and alarms.
D. Row units/Statistics. You can switch off a row unit
here (it will then be marked in grey).
The location of the display and function
buttons may vary between different
terminals but the symbols are always the
same.
If the home screen does not show all
function buttons in the same view, you have
the
button, which toggles to other
function buttons.
By pressing on the field for the feed rate, you can
adjust the feed rate directly on the home screen.
Row units can be switched OFF/ON by pressing
on a row unit.
Navigation buttons
Home screen. This button always takes
you back to the home screen.
Operational settings. This is where the
settings are entered for hydraulic row unit
pressure. (If the machine is equipped with
hydraulic row unit pressure and the
function is activated.)
Basic settings and calibration. No settings
in this menu need to be made during
operation.
Alarms. Press the button to access the
alarms menu. The alarms menu shows a
detailed description of the nature of the
alarm; alarms can also be acknowledged
here. The digit in the button shows the
number of active alarms. This button is
only shown if there are active alarms.
Back. This button is only shown in
submenus and takes you back to the
previous view or the home screen.
11.1.1
Row units
Figure 11.2
Every row unit is displayed with a symbol on the home
screen, and under every row unit two bars are displayed
which monitor the output.
A coloured row unit indicates that the output is active
(also applies to micro-granulate and fertiliser if the
machine is fitted with extra equipment). If, for some
reason, the output on a row unit is switched off, this is
indicated by a greyed-out row unit (the example
indicates that row units 7 and 8 are switched off).
It is possible to switch the output on/off from an
individual row unit directly on the screen by pressing on
24