H.
Bout marker switching
Shows the current position
of the bout marker arms. Press the field to switch
bout marker. Switches manually or automatically
depending on selection with the function button
.
I.
Area meter
Shows area driven since last reset.
During operation, it is a good idea to check at
regular intervals that the air pressure in the seed
feed housing is maintained at 3.5 kPa.
5.3
Function buttons
Figure 5.3
A. Manual output (
B. Transport position
C. LowLift
D. Lift stop
E. Wing folding
F. Auto advance
G. Bout marker switching
H. Front hopper activation
5.4
Row units
Figure 5.4
Every row unit is displayed with a symbol on the home
screen, and under every row unit two bars are displayed
which monitor the output.
A coloured row unit indicates that the output is active
(also applies to micro-granulate and fertiliser if the
machine is fitted with extra equipment). If, for some
reason, the output on a row unit is switched off, this is
indicated by a greyed-out row unit (the example
indicates that row units 7 and 8 are switched off).
It is possible to switch the output on/off from an
individual row unit directly on the screen by pressing on
the row unit to be changed. Restart the output by pressing
the same row unit again.
When you raise and lower the machine, all row
units always start automatically.
Bars
A. Row number
B. The number of doubles – The bar indicates the row
unit’s number of doubles as a percentage.
C. The number of skips – The bar indicates the row
unit’s number of skips as a percentage.
Bar colours
Drilling quality here refers to the number of skips and the
number of doubles.
•
Green bar = drilling quality within approved area.
•
Yellow bar = drilling quality is 50% of set alarm level.
•
Red bar = drilling quality is 100% of set alarm level.
The levels for the different alarms are set in the alarms
menu in basic settings.
903075-en-gb; 07.06.2017
9