7.5
Calibrating the radar
Figure 7.10
Fields on the screen:
A. Resets the number of radar pulses.
B. Records the end of the calibration stretch.
C. Saves the number of radar pulses and calculates the
calibration result in field (F).
D. Displays the total number of radar pulses whilst
operating.
E. Field to enter the distance driven when calibrating.
F. Displays the calibration result as the number of radar
pulses/m.
Calibration
1. Measure a specific distance (minimum 100 m).
2. Press (A) at the starting point to reset the pulse
counter.
3. Drive the selected distance with the machine lowered
to the drilling position and press (B) at the stop point.
4. Press the field (E) and enter the distance driven in
metres.
5. Press button (C). The number of pulses per metre
driven is calculated and automatically updated in
field (F).
20
903075-en-gb; 07.06.2017