5.5.1 Accessing Parameters
When PROG (or SHIFT+PROG) is pressed after application of power or a fault reset,
201,
Input Mode
,
is always the first parameter displayed.
shows a typical programming
display.
Figure 5-3: Typical Programming Display
If a different parameter is accessed and Program mode is exited, that parameter is the first one
displayed the next time Program mode is entered. The drive remembers a different “last parameter
accessed” for Levels 1 and 2.
5.5.2 Changing the Display Scroll Rate
Pressing the
INC
or
DEC
(up or down arrow) keys causes the display to scroll at a slow rate. To
increase the scroll rate, hold the
SHIFT
key at the same time that you press the
INC
key. Release
the
SHIFT
key to return to the slow scroll rate. This procedure works in all programming and
operation modes.
5.5.3 Programming Procedure
To program the value of a parameter, follow these steps:
1. Press the Program (
PROG
) key to enter Level 1 Program mode. To enter Level 2, press
SHIFT+PROG
. The P indicator will appear on the display. You must enter one level of
programming or the other; you cannot switch between levels without exiting Program mode.
that some parameters cannot be changed in Run mode. For example, if you wish to program
parameter
201, Input Mode
, you must stop the drive before beginning programming. Refer to the
at the front of this manual to see which parameters cannot be changed in
Run mode (they appear as shaded entries in the table).
2. Press the
INC
or
DEC
(up or down arrow) keys to access the desired parameter.
3. Press the
SHIFT
key to allow the value to be changed. The P indicator starts to blink.
4. Press the
INC
or
DEC
key to select the new value.
5. Press the
ENTER
key to store the new value. The display shows “Stored” for one second.
6. Press
PROG
to exit Program mode, or the
INC
or
DEC
keys to select a new parameter.
To program a text parameter, follow these steps:
1. Like other parameters, text parameters use the
INC/DEC
(up/down arrow) and
SHIFT
keys
for editing. A line appears under the character that you are changing.
2. Press
SHIFT
to advance to the next character that you want to change.
3. Use the
INC
or
DEC
keys to change the character value.
4. Press
ENTER
to store the edited text.