9
vacon • 146
EtherNet/IP
Local contacts: https://www.danfoss.com/en/contact-us/contacts-list/
9.2
Common Industrial Objects implemented by OPTE9
9.2.1
CIP Objects
9.2.1.1
Identity Object, Class 0x01
The Identity Object provides identification of and general information about the device.
Table 111. Identity Object
Class name
Identity Object
Class identifier
1
Class
Attributes
Id
Access rule
Name
Datatype
Description
1
Get
Revision
UINT
Class revision (1)
2
Get
Max Instance
UINT
Maximum instance num-
ber (1)
3
Get
Number of
Instances
UINT
Number of object
instances(1)
Class Ser-
vices
Id
Name
Description
1
Get_Attributes_All
Get all attributes
14
d
0E
h
Get_Attribute_Single
Get single attribute
Instance
Attributes
Id
Access rule
Name
Datatype
Description
1
Get
Vendor ID
UINT
Vendor identification
2
Get
Device Type
UINT
General type of product
3
Get
Product Code
UINT
Product identification
4
Get
Revision
STRUCT of
Revision of the item the
Identity Object repre-
sents
Major Revision
USINT
Minor Revision
USINT
5
Status
WORD
Summary status of
device
6
Serial number
UDINT
Serial number of the
device
7
Product Name
SHORT
STRING
Human readable identifi-
cation
Instance
Services
Id
Name
Description
1
Get_Attributes_All
Get all attributes
5
Reset
Only reset type 0
14
d
0E
h
Get_Attribute_Single
Get single attribute
Содержание OPTE9
Страница 2: ......