An automation system is a great convenience, in addition to a valid security system, and with just a little, simple care, it is made to last
for years.
Even if your automation device meets all the safety standards, this does not exclude the presence of residual risk, i.e. the possibility that
hazardous situations may be created, usually due to irresponsible or even improper use, and for this reason we wish to offer some advice
regarding the behaviour to be adopted in order to avoid problems:

Prior to using the automation device for the first time

, ask the installer to explain the sources of residual risk to you, and take some

time to read the instruction manual and user information delivered by the installer.
Keep the manual for any future doubts and give it to any new owners of the device.

Your automation device is a machine that faithfully follows your commands

; irresponsible and improper use can make it become

hazardous: do not start movement of the device if there are people, animals or objects within its radius of action.

Children

: installed in accordance with technical regulations, an automation system guarantees a high level of safety.

However, it is prudent to prevent children from playing near the automation device and to avoid unintentional use; never leave the
remote control within the reach of children: it is not a toy!

Anomalies

: as soon as the automation device shows any anomalous behaviour, remove the electricity supply and perform manual

unblocking. Do not attempt any repairs yourself, but ask your installer: in the meantime, the system can operate as a non-automated
device.

Maintenance

: as with all machinery, your automation devices requires periodic maintenance so that it may continue to work for as long

as possible, and in complete safety. Agree a periodic maintenance plan with your installer; V2 SpA recommends a maintenance plan to
be performed every 6 months for normal domestic use, but this period may vary depending on the intensity of use.
Any inspection, maintenance or repairs should only be performed by qualified personnel. Even if you think you know how, do not
modify the system and the automation device programming and adjustment parameters: your installer is responsible for this.
Final testing, periodic maintenance and any repairs should be documented by those performing the operations, and the documents held
by the system owner.

Disposal

: on completion of the device’s operating life, ensure that disposal is performed by qualified personnel and that the materials

are recycled or disposed of in accordance with valid local regulations.

Important

: If your device is fitted with a radio control, the function of which appears to deteriorate over time, or has even ceased to

function, this might simply depend on the batteries being run down (depending on the type, this may be from several months to up to
two/three years). Before contacting your installer, try replacing the battery with the battery from another, working transmitter: if this was
the cause of the problem, then simply replace the battery with another of the same type.

Are you satisfied? 

Should you wish to add another automation device to your home, contact the same installer and ask for a V2 SpA

product: we guarantee you the most advanced products on the market and maximum compatibility with existing automation devices.
Thank you for having read these recommendations, and for any present or future needs, we ask you to contact your installer in full
confidence.

MOTOR UNBLOCKING

Содержание ZORUS

Страница 1: ...ZIS510 IL 341 1 EDIZ 12 12 2019 ZORUS GB IRREVERSIBLE ELECTROMECHANICAL PIVOTING ARM ACTUATOR FOR SWING GATES...

Страница 2: ...165 306 250 62 46...

Страница 3: ...BONS 4 7 ACTIVATION INPUTS 4 8 STOP 4 9 LOW VOLTAGE LIGHT OUTPUT 4 10 COURTESY LIGHTS 4 11 LOCK 4 12 EXTERNAL AERIAL 4 13 PLUG IN RECEIVER 4 14 ADI INTERFACE 4 15 POWER SUPPLY 4 16 BATTERY POWER 4 17...

Страница 4: ...odifications will void the warranty on the product The installation steps should be conducted so as to avoid rainy weather which can expose electronic circuits to dangerous water seepage All operation...

Страница 5: ...are authorised for use and closure is not in a public area Examples of this type are gates inside business premises where the sole users are employees or a part of them who have been suitably informed...

Страница 6: ...Directive 2006 42 EC annex I chapter 1 Low Voltage Directive 2014 35 EU Electromagnetic Compatibility Directive 2014 30 EU Directive ROHS3 2015 863 EU The relevant technical documentation is available...

Страница 7: ...x 0 5 mm2 2 x 0 5 mm2 Photocells RX 4 x 0 5 mm2 4 x 0 5 mm2 4 x 0 5 mm2 Key switch 2 x 0 5 mm2 2 x 0 5 mm2 2 x 0 5 mm2 Flashing light 2 x 1 5 mm2 2 x 1 5 mm2 2 x 1 5 mm2 Antenna integrated into the fl...

Страница 8: ...column 2 Trace a vertical line starting from the point identified and obtain value A 3 Before proceeding with the installation make sure that value A allows to fix the rear bracket otherwise select an...

Страница 9: ...re the arm onto the gear motor using the screw 2 Fix the two arms to each other using the pin and the seger Secure the gear motor to the front bracket 1 Secure the gear motor arm to the bracket using...

Страница 10: ...e cover 3 Unscrew the screw in the motor arm and remove it 4 Fix the limit switches on the motor arm these must also be installed in the presence of mechanical stops on the ground 5 At this point re i...

Страница 11: ...of the manual relating to the Control unit 7 By screwing or unscrewing the two screws A on the motor the two limit switches can be adjusted then using the two screws B block the two adjusting screws...

Страница 12: ...s relevant menu The device can operate without mains power by using the optional battery pack code 161212 Low voltage output that can be used for a signal light or a 24V flashing light Auxiliary relay...

Страница 13: ...tive rubber edges are used the outputs should be connected in cascade and only the final edge should be terminated on the nominal resistance Active edges connected to the accessory power supply are in...

Страница 14: ...d input function can also be activated by pressing i key outside the programming menu or by means of a remote control stored on channel 2 4 8 STOP For a better safety you can fit a stop switch that wi...

Страница 15: ...G it is necessary to turn off the control unit power before doing the operations mentioned here below Pay attention to the way you connect the removable modules MR2 module receiver is provided with 4...

Страница 16: ...B2 Fuse T1 6A 230V 50Hz L N COURTESY LIGHT CONTACT RECEIVER LOCK LAMP 24V 3W 24VDC COM 24VDC Photo TX Edge Test START P STOP COM PHOTO PHOTO I EDGE1 EDGE2 COM BATTERY START ANT M2 M1 Max 500mA 24 Vdc...

Страница 17: ...IN PROGRESS OPENED CONTACT CLOSED CONTACT START PEDESTRIAN START PAUSE GATE OPENED CLOSING IN PROGRESS SAFETY RIBBON 2 OK STOP EXTERNAL PHOTOCELL INTERNAL PHOTOCELL SAFETY RIBBON 1 The control panel...

Страница 18: ...ening direction 4 Verifying Slave motor connection 5 Self training the working times mWARNING Ensure that the motors and accessories are connected correctly prior to performing initialisation Position...

Страница 19: ...tor press OK to move to the next phase If the installation envisages two motors select the doP menu option and press OK The display will show Er94 to indicate that the SLAVE motor is not connected or...

Страница 20: ...times dEF Loading the default parameters ini Control unit initialisation 8 RAPID CONFIGURATION Rapid configuration is a menu allowing the main control unit parameters to be programmed with a few opera...

Страница 21: ...stopped when one of the following conditions is present During slowing During the first work cycle after accessing the programming menu After having powered up the control unit This menu option is use...

Страница 22: ...from the beginning During closure a Start command immediately reopens the gate 8 4 EXITING RAPID CONFIGURATION This menu closes programming both predefined and customised saving the modified data in t...

Страница 23: ...alisation procedure is performed even without working time self training The parameters acquired during initialisation are maintained even when the default parameters are loaded 1 Press and hold the O...

Страница 24: ...point for gate leaf 1 4 4 An opening manoeuvre is performed for each gate leaf the operation terminates when one of the conditions described in part 4 2 occurs the first START stops gate leaf 1 the s...

Страница 25: ...play of thousands or units Area 2 is the reading of the number of cycles before the next request for service its value is rounded down to the hundreds Area 3 is the setup of this latter counter if you...

Страница 26: ...to the length of time set by this menu adjustable time from 0 0 to 1 00 t SEr Lock time 2 0 0 5 1 00 Before the opening phase begins the control unit will energize the electric lock in order to releas...

Страница 27: ...30 100 The displayed value is the percentage of max motor power Pot2 Motor 2 power 100 30 100 The displayed value is the percentage of max motor power Po r1 Power Motor 1 during slow down phase 30 0...

Страница 28: ...n this menu it is possible to adjust the duration of the braking phase The value set is the percentage of the total trip and is equal for both motors during opening and closing St AP Start command dur...

Страница 29: ...ic working is enabled the time of the pause is Ch tr LUCi Courtesy lights This menu allows setting the automatic operating of the courtesy lights during the opening cycle of the gate NOTE If the outpu...

Страница 30: ...sing phase only Warning if you select this option you must disable photocell test Fot i Interior photocell input This menu makes it possible to enable the interior photocell input i e active during op...

Страница 31: ...Motor Release on Mechanical Stop When the gate halts against the mechanical stop the motor is controlled for a fraction of a second in the opposite direction decreasing the motor gear tension 2 0 Func...

Страница 32: ...een set correctly Check that the safety edges enabled from the menu are installed Error 8 When executing a self learning function the control is refused and the display shows Err8 It means that the se...

Страница 33: ...ENGLISH 65...

Страница 34: ...self as well as to human health As indicated by the symbol opposite throwing away this product as domestic waste is strictly forbidden So dispose of it as differentiated waste in accordance with your...

Страница 35: ...ntenance as with all machinery your automation devices requires periodic maintenance so that it may continue to work for as long as possible and in complete safety Agree a periodic maintenance plan wi...

Страница 36: ...ENGLISH 68...

Страница 37: ......

Страница 38: ......

Отзывы: