1.2 - PRELIMINARY CHECKS AND IDENTIFICATION OF THE TYPE TO BE USED

The automation device should not be used until installation, as specified in “Testing and start-up”, has been performed.
It should be remembered that the device does not compensate for defects caused by improper installation, or poor maintenance, thus, prior 
to proceeding with installation, ensure that the structure is suitable and meets current standards and, if necessary, perform any structural 
modifications aimed at the implementation of safety gaps and the protection or segregation of all crushing, shearing and transit zones, and 
verify that:

The gate has no friction points, either during closing or opening.

The gate must be equipped with mechanical stoppers.

The gate is well balanced, i.e. there is no tendency to move spontaneously when stopped in any position.

The position identified for fixing the motor reducer allows easy and safe manual manoeuvring, compatible with the size of the motor
reducer itself.

The support on which the automation device will be fixed is solid and durable.

The mains power supply to which the automation device is connected has a dedicated safety earthing system and differential breaker
with tripping current less than or equal to 30 mA (the breaker gap distance should be greater than or equal to 3 mm).

Warning: The minimum safety level depends on the type of use; please refer to the following outline:

CLOSURE USE TYPE

TYPE OF ACTIVATION 
COMMANDS

GROUP 1

Informed people

(use in private area)

GROUP 2

Informed people

(use in public area)

GROUP 3

Informed people

(unlimited use)

Man-present command

A

B

Not possible

Remote control and closure in 
view (e.g. infrared)

C or E

C or E

C and D or E

Remote control and closure not 
in view (e.g. radio)

C or E

C and D or E

C and D or E

Automatic control
(e.g. timed closure control)

C and D or E

C and D or E

C and D or E

GROUP 1 

-

 

Only a limited number of people are authorised for use, and closure is not in a public area. Examples of this type are gates inside 

business premises, where the sole users are employees, or a part of them who have been suitably informed.

GROUP 2 

- Only a limited number of people are authorised for use, but in this case, closure is in a public area. An example of this may be a 

company gate that accesses onto a public street, and which is only used by employees.

GROUP 3 

- Anyone can use the automated closure, which is thus located on public land. For example the access gate to a supermarket or 

an office, or a hospital.

PROTECTION A 

- Closure is activated by means of a control button with the person present, i.e. with maintained action.

PROTECTION B 

- With the person present, closure is activated by a command controlled by means of a key-switch or the like, in order to

prevent use by unauthorised persons.

PROTECTION C 

- Restricts the force of the leaf of the door or gate. I.e., in the case of the gate striking an obstacle, the impact force must 

fall within a curve established by the regulations.

PROTECTION D 

- Devices, such as photocells, capable of detecting the presence of people or obstacles. They may be active on just one side 

or on both sides of the door or gate.

PROTECTION E 

- Sensitive devices, such as footboards or immaterial barriers, capable of detecting the presence of a person, and installed in 

such a way that the latter cannot be struck in any way by a moving leaf or panel. These devices should be active within the entire “danger 
zone” of the gate. The Machinery Directive defines “Danger Zone” as any zone surrounding and/or near machinery where the presence of 
an exposed person constitutes a risk to the health and safety of that person.

The risk analysis should take into consideration all danger zones for the automation device, which should be appropriately 
protected and marked.

In a clearly visible area, apply a sign with information identifying the motorised door or gate.

The installer should provide the user with all the information relating to automatic operation, emergency opening and 
maintenance of the motorised door or gate.

Содержание ZORUS

Страница 1: ...ZIS510 IL 341 1 EDIZ 12 12 2019 ZORUS GB IRREVERSIBLE ELECTROMECHANICAL PIVOTING ARM ACTUATOR FOR SWING GATES...

Страница 2: ...165 306 250 62 46...

Страница 3: ...BONS 4 7 ACTIVATION INPUTS 4 8 STOP 4 9 LOW VOLTAGE LIGHT OUTPUT 4 10 COURTESY LIGHTS 4 11 LOCK 4 12 EXTERNAL AERIAL 4 13 PLUG IN RECEIVER 4 14 ADI INTERFACE 4 15 POWER SUPPLY 4 16 BATTERY POWER 4 17...

Страница 4: ...odifications will void the warranty on the product The installation steps should be conducted so as to avoid rainy weather which can expose electronic circuits to dangerous water seepage All operation...

Страница 5: ...are authorised for use and closure is not in a public area Examples of this type are gates inside business premises where the sole users are employees or a part of them who have been suitably informed...

Страница 6: ...Directive 2006 42 EC annex I chapter 1 Low Voltage Directive 2014 35 EU Electromagnetic Compatibility Directive 2014 30 EU Directive ROHS3 2015 863 EU The relevant technical documentation is available...

Страница 7: ...x 0 5 mm2 2 x 0 5 mm2 Photocells RX 4 x 0 5 mm2 4 x 0 5 mm2 4 x 0 5 mm2 Key switch 2 x 0 5 mm2 2 x 0 5 mm2 2 x 0 5 mm2 Flashing light 2 x 1 5 mm2 2 x 1 5 mm2 2 x 1 5 mm2 Antenna integrated into the fl...

Страница 8: ...column 2 Trace a vertical line starting from the point identified and obtain value A 3 Before proceeding with the installation make sure that value A allows to fix the rear bracket otherwise select an...

Страница 9: ...re the arm onto the gear motor using the screw 2 Fix the two arms to each other using the pin and the seger Secure the gear motor to the front bracket 1 Secure the gear motor arm to the bracket using...

Страница 10: ...e cover 3 Unscrew the screw in the motor arm and remove it 4 Fix the limit switches on the motor arm these must also be installed in the presence of mechanical stops on the ground 5 At this point re i...

Страница 11: ...of the manual relating to the Control unit 7 By screwing or unscrewing the two screws A on the motor the two limit switches can be adjusted then using the two screws B block the two adjusting screws...

Страница 12: ...s relevant menu The device can operate without mains power by using the optional battery pack code 161212 Low voltage output that can be used for a signal light or a 24V flashing light Auxiliary relay...

Страница 13: ...tive rubber edges are used the outputs should be connected in cascade and only the final edge should be terminated on the nominal resistance Active edges connected to the accessory power supply are in...

Страница 14: ...d input function can also be activated by pressing i key outside the programming menu or by means of a remote control stored on channel 2 4 8 STOP For a better safety you can fit a stop switch that wi...

Страница 15: ...G it is necessary to turn off the control unit power before doing the operations mentioned here below Pay attention to the way you connect the removable modules MR2 module receiver is provided with 4...

Страница 16: ...B2 Fuse T1 6A 230V 50Hz L N COURTESY LIGHT CONTACT RECEIVER LOCK LAMP 24V 3W 24VDC COM 24VDC Photo TX Edge Test START P STOP COM PHOTO PHOTO I EDGE1 EDGE2 COM BATTERY START ANT M2 M1 Max 500mA 24 Vdc...

Страница 17: ...IN PROGRESS OPENED CONTACT CLOSED CONTACT START PEDESTRIAN START PAUSE GATE OPENED CLOSING IN PROGRESS SAFETY RIBBON 2 OK STOP EXTERNAL PHOTOCELL INTERNAL PHOTOCELL SAFETY RIBBON 1 The control panel...

Страница 18: ...ening direction 4 Verifying Slave motor connection 5 Self training the working times mWARNING Ensure that the motors and accessories are connected correctly prior to performing initialisation Position...

Страница 19: ...tor press OK to move to the next phase If the installation envisages two motors select the doP menu option and press OK The display will show Er94 to indicate that the SLAVE motor is not connected or...

Страница 20: ...times dEF Loading the default parameters ini Control unit initialisation 8 RAPID CONFIGURATION Rapid configuration is a menu allowing the main control unit parameters to be programmed with a few opera...

Страница 21: ...stopped when one of the following conditions is present During slowing During the first work cycle after accessing the programming menu After having powered up the control unit This menu option is use...

Страница 22: ...from the beginning During closure a Start command immediately reopens the gate 8 4 EXITING RAPID CONFIGURATION This menu closes programming both predefined and customised saving the modified data in t...

Страница 23: ...alisation procedure is performed even without working time self training The parameters acquired during initialisation are maintained even when the default parameters are loaded 1 Press and hold the O...

Страница 24: ...point for gate leaf 1 4 4 An opening manoeuvre is performed for each gate leaf the operation terminates when one of the conditions described in part 4 2 occurs the first START stops gate leaf 1 the s...

Страница 25: ...play of thousands or units Area 2 is the reading of the number of cycles before the next request for service its value is rounded down to the hundreds Area 3 is the setup of this latter counter if you...

Страница 26: ...to the length of time set by this menu adjustable time from 0 0 to 1 00 t SEr Lock time 2 0 0 5 1 00 Before the opening phase begins the control unit will energize the electric lock in order to releas...

Страница 27: ...30 100 The displayed value is the percentage of max motor power Pot2 Motor 2 power 100 30 100 The displayed value is the percentage of max motor power Po r1 Power Motor 1 during slow down phase 30 0...

Страница 28: ...n this menu it is possible to adjust the duration of the braking phase The value set is the percentage of the total trip and is equal for both motors during opening and closing St AP Start command dur...

Страница 29: ...ic working is enabled the time of the pause is Ch tr LUCi Courtesy lights This menu allows setting the automatic operating of the courtesy lights during the opening cycle of the gate NOTE If the outpu...

Страница 30: ...sing phase only Warning if you select this option you must disable photocell test Fot i Interior photocell input This menu makes it possible to enable the interior photocell input i e active during op...

Страница 31: ...Motor Release on Mechanical Stop When the gate halts against the mechanical stop the motor is controlled for a fraction of a second in the opposite direction decreasing the motor gear tension 2 0 Func...

Страница 32: ...een set correctly Check that the safety edges enabled from the menu are installed Error 8 When executing a self learning function the control is refused and the display shows Err8 It means that the se...

Страница 33: ...ENGLISH 65...

Страница 34: ...self as well as to human health As indicated by the symbol opposite throwing away this product as domestic waste is strictly forbidden So dispose of it as differentiated waste in accordance with your...

Страница 35: ...ntenance as with all machinery your automation devices requires periodic maintenance so that it may continue to work for as long as possible and in complete safety Agree a periodic maintenance plan wi...

Страница 36: ...ENGLISH 68...

Страница 37: ......

Страница 38: ......

Отзывы: