PARAMETER
VALUE
DESCRIPTION
DEFAULT
MEMO
rAM
Starting ramp
1
0 - 4
In order not to stress too much the motor, when the motion starts the
power is gradually increased, until reached the set value or 100% if the
take-off is enabled.
Higher is the set value, longer the length of time of the ramp, that is the
time necessary to reach the value of nominal power.
SEn1
Adjusting the obstacle sensor on motor 1
1.5A
1.0A - 3.5A
This menu allows adjustment of the sensitivity of the obstacle sensor for
motor 1. When the current absorbed by the motor exceeds the value
set, the control unit detects an alarm.
For sensor operation, please refer to the chapter 8.2
SEn2
Adjusting the obstacle sensor on motor 2
1.5A
1.0A - 3.5A
This menu allows adjustment of the sensitivity of the obstacle sensor for
motor 2. When the current absorbed by the motor exceeds the value
set, the control unit detects an alarm.
For sensor operation, please refer to the chapter 8.2
rALL
Braking
30
30 - 100
In the final section of the trip, the control unit drives the motor at reduced
power, depending on the values set for parameters
Po.r1
and
Po.r2
.
In this menu, it is possible to adjust the duration of the braking phase.
The value set is the percentage of the total trip, and is equal for both
motors during opening and closing.
St.AP
Start command during the opening phase
This menu allows fixing the control unit conduct in case it receives a Start
command during the opening phase
PAUS
PAUS
The gate stops and goes to pause
ChiU
The gate immediately starts closing
no
The gate go on with the opening phase (command is ignored)
St.Ch
Start command during the closing phase
This menu allows fixing the control unit conduct in case it receives a Start
command during the closing phase
StoP
StoP
The gate stops and its cycle is considered as finished
APEr
The gate opens again
St.PA
Start command during the pause
This menu allows fixing the control unit conduct in case it receives a Start
command when the gate is open during its pause phase
ChiU
ChiU
The gate starts closing
no
Command is ignored
PAUS
The pause time is reset (
Ch.AU
)
SPAP
Pedestrian Start during the partial opening phase
This menu allows fixing the control unit conduct in case it receives a
Pedestrian Start command during the partial opening phase
PAUS
PAUS
The gate stops and goes to pause
ChiU
The gate immediately starts closing
no
The gate goes on with the opening phase (command is ignored)