ENGLISH
- 61 -
PARAMETER
VALUE
DESCRIPTION
DEFAULT
MEMO
Ch.AU
Automatic closing
In automatic mode, the control unit automatically recloses the gate on
expiry of the time limit set in this menu
no
no
Function deactivated
0.5”-20.0’
The gate recloses after the set period time
(adjustable time from 0.5” to 20.0’)
Ch.tr
Closing after transit
During the automatic operation, the pause count down starts from the set
up value each time a photocell operates during the pause.
If the photocell operates during the opening time, this time will be
immediately stored as pause time.
This function allows having a fast closing as soon as transit through the
gate is completed, therefore, a time shorter than
Ch.AU
is generally used.
Ch.AU
will be used when no is set up.
no
no
Function deactivated
0.5”-20.0’
The gate recloses after the set period time
(adjustable time from 0.5” to 20.0’)
PA.tr
Pause after transit
no
no - Si
In order to let the gate open for the shortest possible time, it is possible
to stop the gate once the passage before the photocells is detected. If
the automatic working is enabled, the time of the pause is
Ch.tr
LUCi
Courtesy lights
This menu allows setting the automatic operating of the courtesy lights
during the opening cycle of the gate.
NOTE:
If the output is used to drive a flashing light (with internal flasher)
select
CiCL
CiCL
CiCL
Light on for the entire duration of the cycle
no
Function deactivated
t.LUC
Timed function (from 0 to 20’)
AUS
Auxiliary channel
This menu allows setting the operating of the relay of the lighting of the
courtesy lights by means of a remote control stored on the channel 4 of
the receiver
Mon
Mon
Monostable operation
tiM
Timed function (from 0 to 20’)
biSt
Bistable operation
SPiA
Setting low voltage exit lights
This menu makes to possible to set the flashing exit function.
FLSh
FLSh
Flasher operation (fixed frequency)
W.L
Indicator light operation: Indicates the status of the gate in real-time. The
type of blinking indicates the four possible conditions:
- GATE STOPPED: Light off
- GATE IN PAUSE: the light is on, fixed
- GATE OPENING: the light blinks slowly (2 Hz)
- GATE CLOSING: the light blinks quickly (4 Hz)
no
Function deactivated
LP.PA
Blinker during pause time
no
no
Function deactivated
Si
The blinker will be on during the pause time too (gate open with
automatic closure active).