ATTENTION
The use operations described in this chapter must be carried out ONLY by
qualified and authorised personnel.
Use personal protective equipment during operation.
In the event of a lack of fuel oil, the solenoid valve closes, the flue gases are
expelled from the flues, the boiler switches off and the pilot light (d)
comes on:
• switch off the machine,
• fill the fuel tank (1),
• reset by pressing the switch (in).
In the event of a water shortage: the machine switches off and the warning
light (f) comes on:
• check the connection to the water mains (2) (low pressure circuit),
• reset by pressing the switch (in).
If there are micro leaks, the machine switches off and the indicator light (e)
flashes:
• check the machine's high-pressure water circuit
• reset by pressing the switch (in).
The machine is equipped with the TST system (Total Stop Timed): it switches
off when the water gun is closed, after 15 seconds and the indicator light (e)
comes on.
The machine is equipped with a TSI system (Total Intelligent Stop), so it
shuts down after 40 minutes from closing the gun. The indicator light (e)
flashes. Reset by pressing the switch (in).
During operation, no-one other than the operators in charge must stand
near the machine or, worse still, intervene on it.
The protections have been designed by the manufacturer in order to
safeguard the safety of the operators while carrying out their tasks.
During operation, the guards must not be removed for any reason.
TROUBLE SHOOTING GUIDE