CHAPTER 10 - CONNECTIONS TO EXTERNAL ENERGY SOURCES
10.1 ELECTRICAL CONNECTION
Electricity for the operation of all electrical components on the machine must be supplied by means of a
cable connected to the general electrical system.
It is compulsory to connect the machine to an earthing system with a resistance value that guarantees
a contact voltage of no more than 25V.
The installation must be carried out in such a way that the connections are not damaged by people or
things and, as far as possible, must be carried out away from transit routes.
Check that the electrical outlet has the required characteristics of conformity and the appropriate
differential protection, in accordance with the standards in force, then connect the outlet (5).
IMPORTANT NOTE:
.Depending on the country where it will be used, the user should check on site what type of network is
present (TN, TT, IT system) and if necessary, install a differential.
• TT system: Protection against contact voltages is only ensured by using the residual current
device.
• tN system, earth leakage circuit breakers should only be used in special cases, such as in small
cross-sections and very long circuits where the above condition cannot be met.
• the IT system does not require earth leakage circuit breakers, as they can compromise the
continuity of operation that led to the choice of the IT system.
Avoid the use of extension cords as far as possible.
WHEN MAKING THE ELECTRICAL CONNECTION, OBSERVE THE VOLTAGE AND FREQUENCY VALUES AS
STATED IN THIS MANUAL AND ON THE CE LABEL.
THE ELECTRICAL CIRCUIT DIAGRAM IS ATTACHED TO THE DOCUMENTATION SUPPLIED WITH THE
MACHINE.
ATTENTION
Connection to the electrical power supply and the earthing system should be carried out
by qualified and experienced personnel, in accordance with the regulations in force.
The electrical power network must be fitted with a circuit breakersuitable for the
machine’s power rating.
In addition, a high-sensitivity residual current circuit breaker with trip threshold
ldn=0.030 A must always be installed