Troubleshooting
12-5
12
When displaying an
image sent from the
machine on the PC, an
image size is shrunk
vertically or
horizontally.
Have you selected
200×100dpi Normal or
200×400dpi Super Fine for
the scan resolution?
Select a scan resolution other than
200×100dpi Normal or 200×400dpi
Super Fine when sending an
image.
—
Dirt on the top edge
or back of the paper.
Check the paper chute and
the ramp.
Open the right cover and check for
toner on the paper ramp inside the
paper transfer unit. Clean the
paper ramp using a soft, dry, lint-
free cloth.
—
Part of the image is
periodically faint or
blurred.
—
Run [Developer Refresh].
9-76
Part of the image is
periodically faint or
shows white lines.
—
Run [Drum Refresh].
9-70
White dots appear on
the image.
—
Run [Drum Refresh].
9-70
Skewed-color
printout.
—
Run [Calibration].
9-75
—
Run [Color Registration].
9-72
Print on the back of
the sheet is visible on
the front.
—
Set [Prevent Bleed-through] to
[On].
4-42
6-25
9-22
The background
density is obtrusive.
—
Run [Background Density Adj.].
4-40
6-22
9-21
Symptom
Checkpoints
Corrective Actions
Reference
Page
Содержание CDC 1930
Страница 1: ...user manual Digital colour Multifunction systems CDC 1945 1950 CDC 1930 1935 ...
Страница 220: ...Printing 5 12 ...
Страница 264: ...Sending Functions 6 44 ...
Страница 422: ...Default Setting System Menu 9 116 ...
Страница 423: ...10 1 10 Management This chapter explains the following operations User Login Setting 10 2 Job Accounting Setting 10 20 ...
Страница 456: ...Management 10 34 ...
Страница 457: ...11 1 11 Maintenance This chapter describes cleaning and toner replacement Regular Maintenance 11 2 Cleaning 11 15 ...
Страница 536: ...Troubleshooting 12 60 ...
Страница 588: ...Rev 2 2011 9 2LCGEEN002 TA Triumph Adler GmbH Betriebsstätte Norderstedt Ohechaussee 235 22848 Norderstedt Germany ...