2AV/X
1-6-46
1-6
1-6-8 Cleaning section
(1) Detaching and refitting the cleaning blade
Follow the procedure below to replace the cleaning blade.
Procedure
1. Remove the image formation unit and the
charger assembly (see page 1-6-40).
2. Remove the MC rail (see page 1-6-44).
3. Remove the drum (see page 1-6-43).
4. Remove the three screws holding the
cleaning blade and then the blade.
Caution: When detaching and refitting the
cleaning blade, take care not to touch the
blade.
Figure 1-6-64
5. Replace the cleaning blade and refit all the
removed parts.
Caution: When fitting the cleaning blade,
position the end of the thrust shaft on the
notch in the thrust gear by turning the gear.
Figure 1-6-65
Cleaning blade
Thrust shaft
Thrust gear
Notch