1-4-13
2AV/X
Description
Maintenance
item No.
1-4
U061
Turning the exposure lamp on
Description
Turns the exposure lamp on.
Purpose
To check the exposure lamp.
Method
1. Press the start key. The screen for executing is displayed.
2. Press the start key. The exposure lamp lights.
3. To turn the exposure lamp off, press the stop/clear key.
Completion
Press the stop/clear key. The screen for selecting a maintenance item No. is displayed.
U063
Adjusting the shading position
Description
Changes the shading position.
Purpose
Used when white lines continue to appear longitudinally on the image after the shading plate is cleaned.
This is due to flaws or stains inside the shading plate. To prevent this problem, the shading position should
be changed so that shading is possible without being affected by the flaws or stains.
Method
1. Press the start key. The screen for adjustment is displayed.
2. Change the setting using the cursor left/right keys.
Description
Shading position
Setting range Initial setting Change in value per step
–5 to +5
0
0.17 mm
Increasing the setting moves the shading position toward the machine right, and decreasing it moves the
position toward the machine left.
3. Press the start key. The value is set.
Interrupt copy mode
While this maintenance item is being performed, copying from an original can be made in interrupt copy
mode.
Completion
Press the stop/clear key at the screen for adjustment. The screen for selecting a maintenance item No. is
displayed.
U065
Adjusting the scanner magnification
Adjustment
See pages 1-6-32 and 34.
U066
Adjusting the leading edge registration for scanning an original on the contact glass
Adjustment
See page 1-6-36.
U067
Adjusting the center line for scanning an original on the contact glass
Adjustment
See page 1-6-37.