2AV/X
1-5-16
Code
Contents
Remarks
Causes
Check procedures/corrective measures
1-5
*: Optional **: Optional for the 15 cpm copier only.
C731
C740
C817
C818
C819
C821
Short-circuited external temperature
thermistor
• The input voltage is below 0.5 V.
Image formation unit connector
insertion problem
• Absence of the image formation unit
is detected continuously for 1500 ms
while there is no error on the copier.
Finisher* front side registration
motor problem
Finisher* rear side registration
motor problem
Finisher* trailing edge registration
motor problem
Finisher* stapler motor problem
Poor contact of
the humidity
sensor PCB
connector
terminals.
Defective external
temperature
thermistor.
Image formation
unit connector
inserted
incorrectly.
Defective image
formation unit
connector.
A problem is
detected with the
front side
registration motor.
A problem is
detected with the
rear side
registration motor.
A problem is
detected with the
trailing edge
registration motor.
A problem is
detected with the
stapler motor.
Reinsert the connector. Also check for
continuity within the connector cable. If
none, repair or replace the cable.
Replace the humidity sensor PCB.
Reinsert the image formation unit
connector if necessary.
Replace the image formation unit.
See the finisher service manual.
See the finisher service manual.
See the finisher service manual.
See the finisher service manual.
Содержание CD 1015
Страница 1: ..._______________________________ UTAX CD 1015 1020 Service Manual ...
Страница 154: ...2AV X 1 5 3 1 5 2 Paper misfeed detection conditions DFSW RSW ESW DFSW ST 1 Figure 1 5 3 ...
Страница 295: ......
Страница 296: ......