2AV/X
1-5-13
Code
Contents
Remarks
Causes
Check procedures/corrective measures
1-5
C100
C104
C200
C310
C400
Exposure lamp problem
• Check the CCD input value for the
lighting status of the exposure lamp
100 ms after the exposure lamp is lit
and the carriage is moved to the
shading position. If the exposure lamp
does not light, turn off the lamp. After
500 ms, light the lamp again and, a
further 500 ms later, check the CCD
input.
The exposure lamp does not light
after 5 retries.
Optical system problem
• After AGC, correct input is not
obtained at CCD.
Drive motor problem
• LOCK ALM signal remains high for 1
s, 1 s after the drive motor has turned
on.
Scanner carriage problem
• The home position is not correct
when the power is turned on or at the
start of copying using the contact
glass.
Polygon motor synchronization
problem
• The polygon motor does not reach a
stable speed within 19 s of the polygon
motor remote signal turning on.
Poor contact of
the connector
terminals.
Defective
exposure lamp.
Defective main
PCB.
Incorrect shading
position.
CCD PCB output
problem.
Poor contact of
the connector
terminals.
CCD PCB output
problem.
Defective main
PCB.
Poor contact of
the drive motor
connector
terminals.
Defective drive
motor rotation
control circuit.
Defective drive
transmission
system.
Poor contact of
the connector
terminals.
Defective scanner
home position
switch.
Defective main
PCB.
Defective scanner
motor.
Poor contact of
the polygon motor
connector
terminals.
Check the connection of connectors CN24,
CN23, CN22 and CN3 on the main PCB,
and the continuity across the connector
terminals. Repair or replace if necessary.
Replace the exposure lamp or inverter
PCB.
Replace the main PCB and check for
correct operation.
Adjust the position of the contact glass
(shading plate). If the problem still occurs,
replace the scanner home position switch.
Replace the ISU.
Check the connection of connectors CN23,
CN22 and CN3 on the main PCB, and the
continuity across the connector terminals.
Repair or replace if necessary.
Replace the ISU.
Replace the main PCB and check for
correct operation.
Reinsert the connector. Also check for
continuity within the connector cable. If
none, repair or replace the cable.
Replace the drive motor.
Check if the rollers and gears rotate
smoothly. If not, grease the bushings and
gears. Check for broken gears and replace
if any.
Check the connection of connectors CN28
and CN25 on the main PCB and the
continuity across the connector terminals.
Remedy or replace if necessary.
Replace the scanner home position switch.
Replace the main PCB and check for
correct operation.
Replace the scanner motor.
Reinsert the connector. Also check for
continuity within the connector cable. If
none, repair or replace the cable.