2AV/X
1-6-50
1-6
(4) Detaching and refitting the fixing heater
Follow the procedure below to replace the fixing heater.
Procedure
1. Remove the fixing unit (see page 1-6-48).
2. Detach the fixing heater connector.
Figure 1-6-72
3. Remove the screw holding each of the fixing
heater front and rear retainers and then the
retainers.
Fixing heater
rear retainer
Fixing heater
front retainer
Figure 1-6-73
4. Pull out the fixing heater from the fixing unit.
5. Replace the fixing heater and refit all the
removed parts.
Figure 1-6-74
Connector
Fixing heater