2AV/X
2-4-13
2-4
Maintenance
Section
part/location
Method
Maintenance cycle
Points and cautions
Page
Optical section
Original size detection
Clean
Every service
Clean the sensor emitter and
(con.)
sensor
receiver with alcohol and then a
dry cloth only if there is a problem.
Maintenance
Section
part/location
Method
Maintenance cycle
Points and cautions
Page
Developing
Developer
Replace
Every service
1-3-8
section
Drum unit
Replace
Every service
Apply GE-334C conductive
1-6-43
grease (P/N A0199040) between
the drum shaft and grounding
plate.
Charger assembly
Replace
Every service
1-6-40
Cleaning lamp
Clean
Every service
Clean with a dry cloth.
Transfer roller assembly
Clean
Clean after every
Vacuum or clean with a dry cloth
100,000 counts
(take care not to damage the
transfer roller).
Check and grease
After every
Check noise. If noise is heard,
100,000 counts
apply grease G501 to the
following locations:
• Contacting surfaces of the
transfer roller and collar
• Contacting surfaces of the
transfer roller and bushing
• Contacting surfaces of the gear
and collar
Check noise. If noise is heard,
apply conductive grease GE334
to the following locations:
• Contacting surfaces of the
transfer roller, bushing and
terminal
Replace
Every 200,000 counts
1-6-45
Doctor blade cover
Clean
Clean after every
Clean with a dry cloth (take care
100,000 counts
not to damage the doctor blade
cover).
Replace
Every 200,000 counts
Seals
Clean
Every service
Vacuum or clean with a dry cloth.
Maintenance
Section
part/location
Method
Maintenance cycle
Points and cautions
Page
Cleaning
Cleaning blade
Replace
Every service
1-6-46
section
Drum separation claw
Check or replace
Every service
Clean with a dry cloth; replace
1-6-43
if the tip is deformed.
Drum shaft
Clean
Every service
Clean with a dry cloth.
Front drum bushing
Clean
Every service
Clean with a dry cloth.
Rear drum bushing
Clean
Every service
Clean with a dry cloth.
Cleaning lower seal
Check or replace
After 200,000 counts
Replace if toner spills due to
1-6-47
wavy or deformed edges of
the seal.
Seals
Clean
Every service
Vacuum or clean with a dry cloth.
Содержание CD 1015
Страница 1: ..._______________________________ UTAX CD 1015 1020 Service Manual ...
Страница 154: ...2AV X 1 5 3 1 5 2 Paper misfeed detection conditions DFSW RSW ESW DFSW ST 1 Figure 1 5 3 ...
Страница 295: ......