Proper Installation 

This water filtering system must be properly installed and located in accordance with the 
Installation Instructions before it is used or the warranty will be void. 

 

Do not  

install or store where it will be 

exposed to temperatures below freezing or 
exposed to any type of weather.  Water 
freezing in the system will break it. Do not 
attempt to treat water over 100°F. 

 

Do not 

install in direct sunlight.  Exces-

sive sun or heat may cause distortion or 
other damage to non-metallic parts. 

 

Properly ground to  conform with all govern-
ing codes and ordinances. 

 

Use only 

lead-free solder and flux 

for all 

sweat-solder connections, as required by 
state and federal codes. 

 

Maximum allowable inlet water pressure is 
125 psi.  If daytime pressure is over 80 psi, 
night time pressure may exceed the maxi-
mum.  Use a pressure reducing valve to re-
duce the pressure. 

 

WARNING: 

Discard all unused parts and 

packaging material after installation. Small 
parts remaining after the installation could 
be a choke hazard. 

 
 

The Fusion Oxi-Gen system provides iron and sulfur removal throughout the home. The Fusion 
Oxi-Gen system should be installed at the point of entry to treat the entire home, both hot and 
cold water. 
 
The Fusion Oxi-Gen system’s backwashing tank removes iron and sulfur using oxidation.  
When water is used in the home, hydrogen peroxide is injected in the Fusion Oxi-Gen feed to 
create super oxidation during operation.  The Catalytic Carbon media in the Fusion Oxi-Gen 
system tank provides filtration when the system is in service to collect contaminants oxidized 
by the hydrogen peroxide.  These contaminants are backwashed from the media surface when 
the system regenerates.   
 
 

Fusion  Benefits 

 

Iron & Sulfur Removal 

 

Virtually maintenance free.  

 

Improves the efficiency of water-using appliances 

 

Simple installation 

 

Safe for landscaping and lawn watering. 

 

Compatible with all on-site and community wastewater treatment systems 

Introduction 

Installation, Operation and Maintenance Manual 

 

FSF-200-OG, FSF-250-OG, FSF-300-OG, 

FSF-500-OG 

Содержание FSF-200-OG

Страница 1: ...10 31 14 Owners Manual Models 089 FSF XXX OG US Water Systems Corporate Office 1209 Country Club Road Indianapolis IN 46234 info uswatersystems com www uswatersystems com 1 800 608 8792 Visit us onli...

Страница 2: ...y Guide Be sure to check the entire system for any shipping damage or parts loss Also note damage to the shipping cartons Contact US Water Systems at 1 800 608 8792 to report any shipping damage withi...

Страница 3: ...terial after installation Small parts remaining after the installation could be a choke hazard The Fusion Oxi Gen system provides iron and sulfur removal throughout the home The Fusion Oxi Gen system...

Страница 4: ...ual Carbon may be multiple boxes Gravel Separate Box Distributor Tube Upper Basket Control Valve Parts Box Solution Tank 8 2 5 Gallons of Peroxide 4 Boxes Stenner Proportional Injection System Panel I...

Страница 5: ...its Fusion Oxi Gen System which utilizes Hydrogen Peroxide or H2O2 Hydrogen peroxide or H2O2 is a powerful yet versatile oxidant that is both safe and effective Considering the H2O2 advantages it s ea...

Страница 6: ...n This reaction is immediate When these contaminants are oxidized with hydrogen peroxide H2O2 the extra oxygen molecule oxidizes the contaminants and the by product is H2O water This is much safer tha...

Страница 7: ...ne The Catalytic Carbon is equipped with a bypass valve CAUTION Water pressure is not to exceed 80 psi water temperature is not to exceed 110 F 43 C and the unit cannot be subjected to freezing condit...

Страница 8: ...e Place the upper basket over the distributor tube and push the valve on the tank Thread the valve on the tank by turning it clockwise Be sure not to cross thread the valve on the tank Tighten the val...

Страница 9: ...mounting bar A level can be used to make sure the bar is installed properly This bar should be secured to the wall studs or wood backing plate that is secured to the wall studs Strainer Filter Sump 30...

Страница 10: ...om the sediment filter to the left side of the injection panel Use the 3 4 Union Adaptors to connect to the panel These adaptors are designed for 3 4 PVC If 1 plumbing is used the 1 x 3 4 Bell Reducer...

Страница 11: ...o not over tighten these unions 5 Now install the strainer filter and the strainer sump If the feed water is high in turbidity use the 100 mesh strainer filter All other applications should use the 30...

Страница 12: ...F 500 OG 1 There is a ball valve on the bottom of the strainer filter sump This ball valve should be closed during operation This ball valve and be used to flush the strainer filter sump period ically...

Страница 13: ...nectors into the bypass valve once they are tight in the plumbing fitting The red clips can then be re installed to se cure the connectors in the bypass valve The inlet and outlet can be identified on...

Страница 14: ...to check the stamped ar rows on the valve and bypass for inlet outlet orientation All piping should be secured to prevent stress on the bypass valve and connectors 7 Install the drain line on the con...

Страница 15: ...sh the 1 4 tubing in the hole in the tank 2 Pull the 1 4 tubing from inside the tank up through the fill hole Then push on the weighted strainer on the 1 4 Tubing Injection Panel Chemical Solution Tan...

Страница 16: ...ch the other end of the 1 4 tubing to the pump on the injection panel Put the nut over the tubing and then the sleeve Push the tubing in the pump fitting and tighten the nut hand tight The connection...

Страница 17: ...mp to the on position and allow the chemical pump to prime with peroxide Typically the peroxide can be seen traveling through the tubing Once the pump is primed unplug the pump from the extension cord...

Страница 18: ...ENERATION Press and release the MANUAL REGEN Button to set a delayed regeneration that will occur at the regeneration time The main dis play page will show DELAYED REGEN ON To cancel press and release...

Страница 19: ...he system is not regenerating during usage hours If there is other backwashing regenerating equipment be sure to offset the regeneration backwash times of each of those units so each unit can backwash...

Страница 20: ...slowly and allow water to enter the unit Allow all air to escape from the unit before turning the water on fully then allow water to run to drain for the entire backwash cycle or until all media fines...

Страница 21: ...nd dissipate immediately This should be the optimal H2O2 injection setting The bubbles should be in the center of the glass and rise to the top immediately Bubbles on the outside of the glass are not...

Страница 22: ...eing overfed with H2O2 This occurs because after installation the water will become cleaner after the plumbing system has been flushed and the initial dosage of H2O2 may need to be adjusted to compens...

Страница 23: ...scolored 6 12 Months Injection Pump Tube Inspect pump tube and replace as need ed 1 5 Years Injection Pump Duck Bill Check Valve Replace injection check valve as need ed 1 5 Years H2O2 Solution Tank P...

Страница 24: ...es Sediment Filter Housings or Chemical Solution Tanks damaged due to environmental issues or improper installation are not covered GENERAL PROVISIONS This warranty does not apply to any commercial or...

Отзывы: