background image

 

 

 

US Water has pioneered the use of hydrogen peroxide in water treatment for the eradication of 
iron (rust) and sulfur (hydrogen sulfide odor) for nearly 20 years. It can truly be called an 
"Eradication System" because it TOTALLY removes iron and sulfur. Properly sized, a Fusion  
Oxi-Gen Hydrogen Peroxide System from US WATER is THE MOST EFFECTIVE METHOD 
for removing iron, rust, sulfur and hydrogen sulfide (the rotten-egg odor) from the water supply. 
The Fusion  Oxi-Gen system uses Catalytic Carbon media in the backwashing filter to collect 
the contaminants removed by the hydrogen peroxide.  Hydrogen Peroxide is not a hazardous 
chemical - to the contrary, hydrogen peroxide (H2O2) is composed of the elements of water: 
Hydrogen and Oxygen. There is nothing foreign or chemically added to the water supply. 
Unlike chlorine, hydrogen peroxide requires no contact time and the reaction (oxidation of iron, 
rust, sulfur and hydrogen sulfide) is immediate. The Fusion Oxi-Gen Hydrogen Peroxide 
System is the answer to practically any iron, rust, sulfur or hydrogen sulfide problem, and is 
backed with our 90-Day 100% Satisfaction Guarantee. US Water Systems guarantees 100% 
iron and sulfur removal with its Fusion  Oxi-Gen System which utilizes Hydrogen Peroxide or 
H2O2.  

 

 
 
 
 
Hydrogen peroxide or H2O2 is a powerful, yet 
versatile oxidant that is both safe and effective. 
Considering the H2O2 advantages, it’s easy to 
see why this is the ONLY sure way to eradicate 
iron and sulfur. 

Powerful

 - H2O2 is one of the most powerful 

oxidizers known and is much stronger than 
chlorine, chlorine dioxide, and potassium permanganate. 

Safe

 - H2O2 is formed by the action of sunlight on water and is a natural purification system for 

our environment. Consequently, H2O2 has none of the problems of gaseous release or 
chemical byproducts that are associated with other chemical oxidants. And since H2O2 is 
totally miscible with water, it reverts back to hydrogen and oxygen after the reaction is 
complete. 

Versatile

 - Hydrogen Peroxide is lethal to iron and sulfur. PERIOD! 

Selective

 - In itself, H2O2 is a fantastic oxidizer, much better than chlorine and potassium 

permanganate. It poses no health hazard and ERADICATES 100% OF THE IRON AND 
SULFUR – ALL THE TIME – GUARANTEED! 
Consult one of water specialists for higher flow rates. US Water offers Fuison Oxi-Gen systems 
up to 100 GPM and can custom design them at no extra charge. Call us at 800-608-8792 or e-
mail us at [email protected] .   

Installation, Operation and Maintenance Manual 

 

FSF-200-OG, FSF-250-OG, FSF-300-OG, 

FSF-500-OG 

System Overview and Specifications 

Содержание FSF-200-OG

Страница 1: ...10 31 14 Owners Manual Models 089 FSF XXX OG US Water Systems Corporate Office 1209 Country Club Road Indianapolis IN 46234 info uswatersystems com www uswatersystems com 1 800 608 8792 Visit us onli...

Страница 2: ...y Guide Be sure to check the entire system for any shipping damage or parts loss Also note damage to the shipping cartons Contact US Water Systems at 1 800 608 8792 to report any shipping damage withi...

Страница 3: ...terial after installation Small parts remaining after the installation could be a choke hazard The Fusion Oxi Gen system provides iron and sulfur removal throughout the home The Fusion Oxi Gen system...

Страница 4: ...ual Carbon may be multiple boxes Gravel Separate Box Distributor Tube Upper Basket Control Valve Parts Box Solution Tank 8 2 5 Gallons of Peroxide 4 Boxes Stenner Proportional Injection System Panel I...

Страница 5: ...its Fusion Oxi Gen System which utilizes Hydrogen Peroxide or H2O2 Hydrogen peroxide or H2O2 is a powerful yet versatile oxidant that is both safe and effective Considering the H2O2 advantages it s ea...

Страница 6: ...n This reaction is immediate When these contaminants are oxidized with hydrogen peroxide H2O2 the extra oxygen molecule oxidizes the contaminants and the by product is H2O water This is much safer tha...

Страница 7: ...ne The Catalytic Carbon is equipped with a bypass valve CAUTION Water pressure is not to exceed 80 psi water temperature is not to exceed 110 F 43 C and the unit cannot be subjected to freezing condit...

Страница 8: ...e Place the upper basket over the distributor tube and push the valve on the tank Thread the valve on the tank by turning it clockwise Be sure not to cross thread the valve on the tank Tighten the val...

Страница 9: ...mounting bar A level can be used to make sure the bar is installed properly This bar should be secured to the wall studs or wood backing plate that is secured to the wall studs Strainer Filter Sump 30...

Страница 10: ...om the sediment filter to the left side of the injection panel Use the 3 4 Union Adaptors to connect to the panel These adaptors are designed for 3 4 PVC If 1 plumbing is used the 1 x 3 4 Bell Reducer...

Страница 11: ...o not over tighten these unions 5 Now install the strainer filter and the strainer sump If the feed water is high in turbidity use the 100 mesh strainer filter All other applications should use the 30...

Страница 12: ...F 500 OG 1 There is a ball valve on the bottom of the strainer filter sump This ball valve should be closed during operation This ball valve and be used to flush the strainer filter sump period ically...

Страница 13: ...nectors into the bypass valve once they are tight in the plumbing fitting The red clips can then be re installed to se cure the connectors in the bypass valve The inlet and outlet can be identified on...

Страница 14: ...to check the stamped ar rows on the valve and bypass for inlet outlet orientation All piping should be secured to prevent stress on the bypass valve and connectors 7 Install the drain line on the con...

Страница 15: ...sh the 1 4 tubing in the hole in the tank 2 Pull the 1 4 tubing from inside the tank up through the fill hole Then push on the weighted strainer on the 1 4 Tubing Injection Panel Chemical Solution Tan...

Страница 16: ...ch the other end of the 1 4 tubing to the pump on the injection panel Put the nut over the tubing and then the sleeve Push the tubing in the pump fitting and tighten the nut hand tight The connection...

Страница 17: ...mp to the on position and allow the chemical pump to prime with peroxide Typically the peroxide can be seen traveling through the tubing Once the pump is primed unplug the pump from the extension cord...

Страница 18: ...ENERATION Press and release the MANUAL REGEN Button to set a delayed regeneration that will occur at the regeneration time The main dis play page will show DELAYED REGEN ON To cancel press and release...

Страница 19: ...he system is not regenerating during usage hours If there is other backwashing regenerating equipment be sure to offset the regeneration backwash times of each of those units so each unit can backwash...

Страница 20: ...slowly and allow water to enter the unit Allow all air to escape from the unit before turning the water on fully then allow water to run to drain for the entire backwash cycle or until all media fines...

Страница 21: ...nd dissipate immediately This should be the optimal H2O2 injection setting The bubbles should be in the center of the glass and rise to the top immediately Bubbles on the outside of the glass are not...

Страница 22: ...eing overfed with H2O2 This occurs because after installation the water will become cleaner after the plumbing system has been flushed and the initial dosage of H2O2 may need to be adjusted to compens...

Страница 23: ...scolored 6 12 Months Injection Pump Tube Inspect pump tube and replace as need ed 1 5 Years Injection Pump Duck Bill Check Valve Replace injection check valve as need ed 1 5 Years H2O2 Solution Tank P...

Страница 24: ...es Sediment Filter Housings or Chemical Solution Tanks damaged due to environmental issues or improper installation are not covered GENERAL PROVISIONS This warranty does not apply to any commercial or...

Отзывы: