AUTOMATION
MAU500ERP(X)
GATE
CLOSED
GATE NOT CLOSED
PB
OPTIONAL
1
1
L
1
2
3
4
5
6
7
8
Open A
0V
OPEN
CLOSE
STOP
Open B
Stop NC*
Stop NO*
Etat +
Etat
-
N
L
230VAC~
50Hz
+24V
0V
10A
N
LED
CONNECT
LINE
NEUTRAL
D600V
D600V
Technical Specifications
Mains voltage :
230V +/- 15% - 50Hz
Max. load:
2A - 24Vdc
Module consumption:
< 1VA - < 0.3W
Wiring:
Maximum section of cables to be used for mains
voltage: 2.5 mm²
Action type:
1.C
Pollution degree:
2
Rated surge voltage:
2500V
Resistance of plastic
to incandescent:
from 75°C to 125°C.
Ambient temperature:
from -20°C to +40°C
Relative humidity :
0 - 70%
Dimensions :
58 x 84 x 20 mm
WIRING
AUTOMATION ACTUATOR MODULE
DS1054-207B
MaU500erP
5454475
automation actuator module
MaU500erPX
5454476
automation actuator module with external
aerial
radIO raNGe:
POWer range:
• Inside 100 m² apartments with perpendicular
crossing of main wall or ceiling.
• 250 m in open range
(Note: in both cases the range may be reduced
by the presence of metallic elements, crossing
of walls, or partitions).
radIO TraNSMISSION:
The transmitter Led will light up only if the
radio transmission was successful.
Adding an intermediate receiver will solve the pro-
blem of an insufficient range.
Refer to the transmitter instruction booklet for
more information.
GB
all YOKIS receivers are compatible with YOKIS transmitters
(remote controls, wall-mounted remote controls,
flush-mounted transmitters).
P7
* Wire the automation STOP
according to the behaviour of the
automation to be controlled:
> On Terminal 5 of MAU500ERP(X)
in case of a NC STOP input (e.g.
FAAC gates).
> On Terminal 6 of MAU500ERP(X)
in case of a NO STOP input.
Installing Cautions
– In order to follow the safety rules, the module must be connected to a power line that is upstream protected by a magneto-
thermic switch 10A C curve used as overload protection and circuit breaker device.
– Important: The product does not have consolidated insulation between the “Connect” button, the test button, the LED and
the circuit powered by the network; use appropriate insulating tools to access these buttons.
– The module must be installed only by qualified personnel and into a place the end-user cannot access, inside a casing with
IPx4 waterproof enclosure, according to the installing national rules.
– The module must be fixed with screws in the holes provided for this purpose to prevent any movement of the module inside
the control box of the gate.