27
Initial Installation
QUALIFIED INSTALLERS ONLY
Optional: False Ceiling -
If your ceiling dimension is greater than the minimum (Figure 39) You may want
the CSS Air discharge lower on the wall. To do this a false ceiling is required to properly evacuate the heat
from the chase. (See Figure 40).
3"
76mm
Minimum
False Ceiling
121mm
Minimum
4
3
"
4
Figure 42: Option 2
Figure 43: Open Chase Iso View
Figure 40: False Ceiling
Option 2: Open Chase (built-out installations) - This could be considered the most discreet option
when considering the CSS. The chase must be constructed in a way that stops short of the ceiling, leaving
it totally vented above. Minimum framing dimensions must be followed when constructing this option and
not to deviated from them when using combustible materials. Consider
Optional 3: Valance to work in
conjunction with this option.
2" MIN
3”
3"
76mm
Minimum
121mm
Minimum
6"
152mm
Minimum
Wall Mounted Object
4
3
"
4
Figure 41: False Ceiling Iso View